Prod Model: |
LC1-D65 |
Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Model No: |
LC1-D LC1-Dn |
Function: |
AC Conactor |
Certification: |
CE CCC |
Operation: |
Manual Type |
Rated Current(a): |
AC4 |
Volt: |
24V-660V |
Hz: |
50/60Hz |
Number Of The Contacts: |
3p+No 3p+Nc |
Circumstance Temperature: |
-5°c~40°c |
Brand: |
Suntree/OEM |
Size: |
Miniature |
Theory: |
Electromagnetic Relay |
Usage: |
Communication Relay |
Protective Characteristics: |
Open Relay |
Load: |
High Power Relay |
Action Principle: |
Electronic Type |
Product Description
CJX2-6511 LC1-D65 AC 230V telemechanic contactor
LC1-D AC contactor
Application
1)LC1-D series AC Contactor
is suitable for using in the circuits up to the rated voltage 660V AC50Hz or 60Hz,
rated current up to 95A, for making, breaking, frequently starting & controllingthe AC motor.
2)Combined with the auxiliary contact block, timer delay & machine-interlockingdevice etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.With the thermal relay, it is combined into the electromagnetic starter.
3)The product conforms to IEC60947-4-1 CE stardand.
Standard Control Circuit Voltage
Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 600 |
50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
60Hz | B6 | D6 | E6 | F6 | M6 | - | U6 | Q6 | - | - | R6 | - | - |
50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | - | - |
LC1-D AC contactor Technical Data
Type | LC1-D09 | LC1-D12 | LC1-D18 | LC1-D25 | LC1-D32 | LC1-D40 | LC1-D50 | LC1-D65 | LC1-D80 | LC1-D95 |
Rated working current (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 |
Standard power ratingsof 3-phase motors 50/60Hz in category AC-3 | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 |
415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | 55 | 55 |
660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 |
Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 |
Electrical life | AC3 (x104) | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
AC4 (x104) | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 |
Mechanical life (x104) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 |
Number of the contacts | 3P+NO | 3P+NC+NO |
3P+NC |
LC1-D AC contactor Dimensioned
Type | A | B | C | D | E | a | b | |
LC1-D09~12 | 47 | 76 | 82 | 113 | 133 | 34/35 | 50/60 | 4.5 |
LC1-D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 4.5 |
LC1-D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 4.5 |
LC1-D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 4.5 |
LC1-D40~65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 6.5 |
LC1-D80~95 | 87 | 129 | 127 | 175 | 195 | 40 | 100/110 | 6.5 |
LC1-DN AC contactor
Application
1)LC1-DN series AC contactor is suitable for frequency 50/60Hz, rated insulation voltage up to1000V,
rated operation current 9~150A under AC-3 duty. It is mainly used for making/breaking electric circuits at a long distance & for frequent
starting/stopping & controlling AC Motors.
2)It isused in combination with thermal relay to compose a magnetic motor starter.
3)The products com-ply with IEC60947-4-1 standard.
Standard Control Circuit Voltage
Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 600 |
50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
60Hz | B6 | D6 | E6 | F6 | M6 | - | U6 | Q6 | - | - | R6 | - | - |
50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | - | - |
LC1-DN AC contactor Technical Data
Type | LC1-DN09 | LC1-DN12 | LC1-DN18 | LC1-DN25 | LC1-DN32 | LC1-DN38 | LC1-DN40 |
Rated working current Ie (A) AC-3 Ue≤440V | 9 | 12 | 18 | 25 | 32 | 38 | 40 |
Rated hear current Ith (A) | 25 | 25 | 32 | 40 | 50 | 50 | 60 |
Rated insulation voltage Ui (V) | 690 | 690 | 690 | 690 | 690 | 690 | 1000 |
Rated operating voltage Ue (V) Max | 690 | 690 | 690 | 690 | 690 | 690 | 1000 |
Rated operational power in AC-3 Pe (KW) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 9 | 11 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 18.5 |
415/440V | 4 | 5.5 | 9 | 11 | 15 | 18.5 | 22 |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 18.5 | 22 |
660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 18.5 | 30 |
Rated operational power in AC-4 Pe (KW) | 220/230V | 1.5 | 1.5 | 2.2 | 3 | 4 | 4 | 4 |
380/400V | 2.2 | 3.7 | 4 | 5.5 | 7.5 | 7.5 | 9 |
415/440V | 2.2 | 3 | 3.7 | 5.5 | 7.5 | 7.5 | 9/11 |
500V | 3 | 4 | 5.5 | 7.5 | 9 | 9 | 11 |
660/690V | 4 | 5.5 | 7.5 | 10 | 11 | 11 | 15 |
Frequency of operation (I/h) | | 1200 | 1200 | 1200 | 1200 | 1000 | 1000 | 1000 |
Electrical endurance (x104) | AC-3 | 100 | 100 | 100 | 100 | 80 | 80 | 80 |
AC-4 | 20 | 20 | 20 | 20 | 20 | 20 | 15 |
Mechanical endurance (x106) | | 15 | 15 | 15 | 15 | 15 | 15 | 6 |
Operating voltage range of coil | Close voltage:(0.85~1.1)Us Open voltage:(20%~75%)Us |
Power consumption of coil (VA) | Atracting | 7 | 7 | 7 | 7 | 7 | 7 | 20 |
Starting | 70 | 70 | 70 | 70 | 70 | 70 | 200 |
Rated insulation voltage of auxitiary contacts (V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Conventional thermal current of auxitiary contacts (A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Auxitiary contacts speecification | AC-15:360VA DC-13:33W |
Type | LC1-DN50 | LC1-DN65 | LC1-DN80 | LC1-DN95 | LC1-DN115 | LC1-DN150 |
Rated working current Ie (A) AC-3 Ue≤440V | 50 | 65 | 80 | 95 | 115 | 150 |
Rated hear current Ith (A) | 80 | 80 | 125 | 125 | 200 | 200 |
Rated insulation voltage Ui (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated operating voltage Ue (V) Max | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated operational power in AC-3 Pe (KW) | 220/230V | 15 | 18.5 | 22 | 25 | 30 | 40 |
380/400V | 22 | 30 | 37 | 45 | 55 | 75 |
415/440V | 25/30 | 37 | 45 | 45 | 59 | 80 |
500V | 30 | 37 | 55 | 55 | 75 | 90 |
660/690V | 33 | 37 | 45 | 45 | 80 | 100 |
Rated operational power in AC-4 Pe (KW) | 220/230V | 5.5 | 7.5 | 7.5 | 9 | 9 | 11 |
380/400V | 11 | 11 | 15 | 15 | 18.5 | 22 |
415/440V | 11 | 11/15 | 15 | 15 | 18.5 | 22 |
500V | 15 | 18.5 | 22 | 22 | 30 | 37 |
660/690V | 18.5 | 22 | 25 | 25 | 30 | 45 |
Frequency of operation (I/h) | | 1000 | 1000 | 750 | 750 | 750 | 750 |
Electrical endurance (x104) | AC-3 | 60 | 60 | 60 | 60 | 60 | 60 |
AC-4 | 15 | 15 | 15 | 15 | 15 | 15 |
Mechanical endurance (x106) | | 6 | 6 | 4 | 4 | 4 | 4 |
Operating voltage range of coil | Close voltage:(0.85~1.1)Us Open voltage:(20%~75%)Us |
Power consumption of coil (VA) | Atracting | 20 | 20 | 20 | 20 | 22 | 22 |
Starting | 200 | 200 | 200 | 200 | 300 | 300 |
Rated insulation voltage of auxitiary contacts (V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Conventional thermal current of auxitiary contacts (A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Auxitiary contacts speecification | AC-15:360VA DC-13:33W |
LC1-DN AC contactor Dimensioned
Type | 09 | 12 | 18 | 25 | 32 | 38 | 40 | 50 | 65 | 80 | 95 | 115 | 150 |
b | 76.6 | 76.6 | 76.6 | 76.6 | 76.6 | 76.6 | 127 | 127 | 127 | 127 | 127 | 158 | 158 |
c | 87 | 87 | 87 | 94 | 94 | 94 | 116 | 116 | 116 | 123.8 | 123.8 | 132 | 132 |
LC1-F AC contactor
Application
LC1-F series
AC contactor is applicable in the circuits up to the rated voltage 1000V AC 50Hz or 60Hz,rated
curent 780A, for long distance breaking circuit and frequently starting or control the motor.
It also can be used for the control of distribution circuits of rated current from 200A TO 1600A.
LC1-F AC contactor Technical Data
Type | LC1-F115 | LC1-F150 | LC1-F185 | LC1-F225 | LC1-F265 | LC1-F330 | LC1-F400 | LC1-F500 | LC1-F630 |
Rated operation current (A) | AC-3 | 115 | 150 | 185 | 225 | 265 | 330 | 400 | 500 | 630 |
Standard power ratings of 3-phase motors AC-3(KW) | 220V | 30 | 40 | 55 | 63 | 75 | 100 | 110 | 147 | 200 |
380V | 55 | 75 | 90 | 110 | 132 | 160 | 200 | 250 | 335 |
415V | 59 | 80 | 100 | 110 | 140 | 180 | 200 | 280 | 375 |
440V | 59 | 80 | 100 | 110 | 140 | 200 | 250 | 295 | 400 |
500V | 75 | 90 | 110 | 129 | 160 | 200 | 257 | 335 | 400 |
660V | 80 | 100 | 110 | 129 | 160 | 200 | 280 | 335 | 450 |
1000V | 65 | 65 | 100 | 100 | 147 | 160 | 185 | 335 | 450 |
Xinchi Electric Co., Ltd. is the best one, which stands out above the rest in China intelligent low voltage electrical field, meanwhile it is a grouping company in the "city of electrical".There are four branch companies subordinate to it:Yueqing Xinchi Electric Sci-Tech Co., Ltd, Yueqing Imp&Exp Co., Ltd, HK Yangming Electrical Technology Co., Ltd and Wenzhou Litto smart Co., Ltd.Moreover.There are 320 workers, the annual output value breakthrough one hundred million, and the export value arrive at ten million.
We always pay attention to manufacture and sell automatic industrial and control system, modular intelligent electrical equipments, such as circuit breakers, residual circuit breakers, contactors, isolators, solid state relay, control and protect switch, automatic transfer switch, electrical fire detecting system, surger protect device, multifunctional meter and new energy system fittings etc.
Especially DC circuit breaker, DC isolating switch, DC fuse, busbar chamber, waterproof switch and other products with leading technical level in this field...We are the first domestic company with CE, CB, IEC, Nemko, SAA, TUV, ISI and CCC certification.Our products are widely used by domestic famous enterprises, and it has become a OEM partner of many international famous brands.
We have fully implement the IS09001:2008 quality management system.It adopts advanced production equipment and precision detecting equipment, introduces high-tech process and high technology talents to provides powerful guarantee for product development, quality upgrading and management innovation of the company.
In order to seek after the excellence, Xinchi will continue to carry on the spirit of "practice, honesty, innovation, active", insist on the policy of " technology promotes industry, Brand promotes industrial", and we believe in "Technology innovation, famous in the world", working hard to let"XINCHI electric brand"walk towards to the world.