Home >> Manufacturers Directory>> Fuse

>> Switch Fuse

15kv-27kv Expulsion Fuse Cutout and Load Switching Fuse Cutout

Conditions of UseAmbient temperature: Not higher than +40 ºC, not less than -30 ºCAltitude: Not exceed 1000m (1000m above can be corrected GB311.1-1997)Power frequency: 50 ±2HzEarthquake intensity: 7degrees belowMaximum wind speed: 35m/s TypeRatedvoltage(kV)Ratedcurrent (A)Breakingc

Zhejiang Fuerte Electrical Apparatus Co., Ltd.

Cut out Fuse 35kv

Product modelHRW10-35F/100HRW10-35F/200(KV) Rated Voltage3535(A)Rated Current100200(KA)Rated circuit break current (KA)512.5(KV)Impulse voltage (KV)185185(KV)P.F. withstand voltage (KV)7070Produce:Certificate:Please contact us for more information. We can design and manufacture specially on your req

Zhong Rui Electric Co., Ltd.

High Voltage Limit Current Fuse for Protection Transformer (Germany DIN Standard)

It can be used inindoor system of 50Hz and rated voltage of 3.6KV, 7.2Kv, 12KV, 24KV, 40.5KV: Used together with other switch facilities such as loading swithes, vacuum contactors, it can protecti electric transformers and other electric facilities against overloading or circuit break. It is also an

Zhejiang Zhiguang Fuse Co., Ltd.

Tp1 Thermostat for Motor Protection with UL Certification

Using scope:Applies to the fractional electric motor, coils, liquid pumps, fluorescent ballast, the washer electrical machinery, the air conditioner electrical machinery, the transformer, the illumination lamps and lanterns, the automobile electrical machinery and similar household electrical applia

Hengxin Precision Electrical Equipment Co., Ltd.

Good Price BS Standard W Type Busbar Installation Fuse

Good price BS standard W Type busbar installation FuseProduct Description1.H.V current-limiting fuses typeW isdesigned for protection ofmotors or other power equipments working under avoltage of 3.6kV, 7.2kV, 50Hz, and with a rated currentup to 224A from overloading or shortcircuit.It can also be us

Wenzhou Shuguang Fuse Co., Ltd.

High Voltage 10kv-15kv Porcelain Expulsion Drop Fuse Cutout

Conditions of UseAmbient temperature: Not higher than +40 ºC, not less than -30 ºCAltitude: Not exceed 1000m (1000m above can be corrected GB311.1-1997)Power frequency: 50 ±2HzEarthquake intensity: 7degrees belowMaximum wind speed: 35m/sPRODUCT DESCRIPTIONFSC-1 medium voltage overhe

Zhejiang Fuerte Electrical Apparatus Co., Ltd.

Cutout Fuse 27kv (PRW-38)

CUT-OUTGama 20 kV a 36 kV- Circuito Principal 200 A- Ith 8 kA.- Montaje Vertical- Tubo Fusible de 100 A- Norma CEI 282-2- Tubo Fusible compatible con losestándar norteamericanos.- Este modelo permite el montajede la Autoválvula directamentesobre la escuadra de fijación.- Eslabon

ORIENT ELECTRIC INTERNATIONAL GROUP LIMITED

15kv-100A Porcelain Drop out Fuse Cutout

Condition of Use:1. The ambient air temperatures within the range of -30 degreeto +40 degree;2. The altitude above sea level not exceeding 1, 000m; (If the altitude is higher than 1, 000, it needs adjust. )3. Frequency of the A. C. Power supply not less than 48Hz and not exceeding 52Hz;4. Earthquake

Zhejiang Zhongneng Electrical Co., Ltd.

Tp2 Thermostat with UL and VDE Certification

Using scope:Applies to the fractional horsepower motor, fluorescent ballasts, motor of washer,motor of air conditioner, transformers, lighting lamps, DC motor of automobile,battery changer, household electric appliances, OA-machines etc.Best seller point :Miniature Size, Superior heat response, Rapi

Hengxin Precision Electrical Equipment Co., Ltd.

High Quality Miniature Circuit Breaker 100A MCB

COB-63 Minature Circuit Breaker1. Beautiful product appearance, flexible operation, good electrical contact, width of 2P is 36mm.2. Rated Current: In=100A3. Rated Voltage: Un=AC 400V/230V4. Breaking Capacity: 7.5kA/10kA Mechanical Life: 20000times5. Working temperature:-40ºC~+70ºC6. Materi

Zhejiang Kangge Electric Co., Ltd.

Outdoor Cutout Fuse 100-200A Porcelain Fuse Cut out

GeneralDrop-out fuse and pull the load drop-out fuse is outdoor high-voltage protection of electrical. It is installed in high-voltage side of the distribution transformer or the Support Link of the distribution line as Transformers and lines short circuit, overload protection, and open, co-load cur

Zhejiang Fuerte Electrical Apparatus Co., Ltd.

High Voltage Limit Current Fuse for Protection Electrical Motor (England BS Standard)

The product can be used in indoor Ac system of 50Hz and rated voltage 3.6kV and 7.2KV 12Kv. When used together with other protection facilitles(such as switches and vauum contactors),it works to protect high-volttage motor and other electric facilities from overloading and circrit break.Main technic

Zhejiang Zhiguang Fuse Co., Ltd.

12kv Outdoor Expulsion Drop-out Type Distribution Fuse Cutout

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout 12KVApplication: Protection device for protecting power system from over-load and short-circuit failure.Ratings: 11kV-36kV.Standards: IEC 600282-2Features:1, High over-current protection capability, high breaking current.2, High industrial fre

Zhejiang Haivo Electrical Co., Ltd.

Porcelain Expulsion Fuse Cutout / Dropout Fuse

We mainly produce and sell high & low voltage electrical fittings: Fuses, circuit breakers, contactors, relays, plug&sockets, etc.12KV, 15KV, 33KV, 36KV, etcRated voltage (KV)Rated current (A)Rated frequency(Hz)Power frequency withstand voltage(Dry)(KV)Power frequency withstand voltage(Wet)(KV)Light

Cowin Electrical Co., Ltd.

Seki St-22 Thermostat for Overload Protection

Using scope:Applies to motor of fan, fluorescent ballast, battery changer, electron equipment ,industry and household electric appliances, OA-machines etc, supply reliable over-heating protect.Key Technical Parameters:Rated voltage: 50/60HZ, 250V, ACNominal current: 5 AFixed open temperature scope:

Hengxin Precision Electrical Equipment Co., Ltd.

High-Voltage Current Limiting Fuse for Transformer Protection

This product applies to the indoor AC 50 ~ 60Hz system with the rated voltage of 3.6~40.5kV, and may be used along with other switching devices(such as load switch, vacuum contactor, etc.) as short-circuit and overload protection element for the power transformer and other power equipment. The produ

Xi'an Xiangyuan Zhenli Electric Co., Ltd.

Fsc-1 Medium Voltage Overhead Line Overload Protection Porcelain Dropout Fuse Cut out

PRODUCT DESCRIPTIONFSC-1 medium voltage overhead line overload protection porcelain dropout fuse cut outTechnical SpecificationsTypeRated Voltage(KV)Rated Current(A)Breaking Current(A)Impulse Voltage(BIL)Power-frequency withstand voltage(KV)Leakage Distance(MM)FSC-11510010000110402201520012000110402

Zhejiang Fuerte Electrical Apparatus Co., Ltd.

Ry-01 Series Metal House Radical Lead Thermal Fuse 250V 10A 15A 72-240'c

RY01 series thermal fuse is anon-resetting protective device, which is used to prevent various electrical and heating appliance, dynamoelectric tools and industrial equipment from overheating. When the working temperature exceeds the rated value, the molten substance would cut the circuit rapidly an

Focus Sensing and Control Technology Co., Ltd.

Fuse Cutout 33kv 100A

CUT-OUTGama 20 kV a 36 kV- Circuito Principal 200 A- Ith 8 kA.- Montaje Vertical- Tubo Fusible de 100 A- Norma CEI 282-2- Tubo Fusible compatible con losestándar norteamericanos.- Este modelo permite el montajede la Autoválvula directamentesobre la escuadra de fijación.- Eslabon

ORIENT ELECTRIC INTERNATIONAL GROUP LIMITED

Outdoor Polymeric Expulsion Drop-out Type Distribution Fuse Cutout

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout with arc extinguishing chamber 15KVApplication: Protection device for protecting power system from over-load and short-circuit failure.Ratings: 11kV-36kV.Standards: IEC 600282-2Features:1, High over-current protection capability, high breaking

Zhejiang Haivo Electrical Co., Ltd.