Must RS232 Port EP3000 PRO 1-6kw Power InverterModel:EP3000 PRO 1-6KW
Features
1.1kw~6kw optional, 12V / 24V / 48VDC optional
2. Max. Charge current 65A.
3. Pure sine wave.
4. Inbuilt pure copper transformer
5. Support inductive load
6. Automatic three-stage battery charger (bulk, absorption, float)
7. With 150cm battery cable
8. Support generator
9. Support solar system
10. Remote control / RS232 optional
11. CE/ SONCAP certificate
12. Charge current adjustable: 25%, 50%, 75%, 100%
13. Input range: 100-127VAC, output: 120VAC
14. Input range: 155-265vavc, output: 230VAC
15. Input frequency: 40-80Hz, output: 50/60Hz
Protection Features
A. Battery over voltage and under voltage protection
B. Over temperature protecton
C. Automatic overload protection
D. Short circuit protection
Specifications
MODEL | 120V Models | 230V Models |
OUTPUT |
Power Levels crated at nominal inputs | 1KW;2KW;3KW;4KW | 1KW;2KW;3KW;4KW;5KW;6KW |
Output Voltage | 100V/110V/120V Selectable | 220V/230V/240V Selectable |
Voltage Waveform | Pure Sine wave |
Crest Factor | 3:'1 |
Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal |
(Synchronized to Mains) |
short circuit protection | Circuit breaker |
Over load protection | Circuit breaker |
Capable of motor | 1kw/2kw: 1HP, 3kw/4kw: 2HP, 5kw/6kw 3HP |
Transfer time (DC to AC) | 10 ms |
protection | Over load protection |
Over temperature protection |
Output short circuit protection |
INPUT |
Nominal Voltage | 100V/110V/120V Selectable | 220V/230V/240V Selectable |
Input Frequency | 40Hz ~ 80Hz, 50/60Hz auto-sensing |
Efficiency (Normal mode) | 95% |
Noise Filtering | Full time EMI/RFI filtering |
Inverter breaker size | 1kw: 10A, 2kw-6kw:30A | 1kw: 10A, 2kw-6kw: 30A |
|
Voltage Range | 100V ~ 127V | 155V ~ 265V |
Inverter main features | low frequency |
huge charge current |
pure copper transformer |
supports inductive loads |
Surge Protection | 350 Joules | 350 Joules |
|
BATTERY |
Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) |
DC Voltage | 1KW/2KW/3KW:12Vdc | 1KW/2KW/3KW:12Vdc |
2KW/3KW/4KW:24Vdc | 2KW/3KW/4KW:24Vdc |
3KW/4KW:48Vdc | 3KW/4KW/5KW/6KW:48Vdc |
Typical backup time | Up to external battery |
Charging method | Battery charger: (bulk,absorption, and float) |
charge current is adjustable: 25% 50% 75% 100% optional |
Maximum charging current | 1000W 12V:35A | 2000W 12V:65A |
2000W 24V:35A | 3000W 12V:65A |
3000W 24V:45A | 4000W 48V:35A |
5000W 48V:40A | 6000W 48V:50A |
Average charging | Quick charging mode:15.7V-54V maximum. |
voltage for each battery | Trickle charging mode:13.5V -52V |
Protection | Over current protection & Over charging voltage protection |
Battery over voltage & low voltage protection |
When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate |
Monitoring | RS232 communication port |
remote control cable 10 meters |
SOLAR CHARGER |
Rating voltage | 12V / 24V / 48V | 12V / 24V / 48V |
DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc |
Charging method | Constant voltage with current limiting by PWM control |
Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc |
Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) |
24V model : 1000W/2000W (27.0Vdc @ 37A) |
48V model : 3KW/5KW/6KW (54Vdc @ 18.5A) |
Protection | DC input polarity protection, DC input short circuit protection( when battery is |
connected), DC output over current protection |
COMMUNICATIONS & MANAGEMENT |
Standard Interface port | RS232 |
Optional Interface part | RJ45 (Surge protection), DB9 |
Control panel | LED/LCD optional |
Audible alarm | Alarm on battery:Low battery & Battery over voltage |
Alarm on abnormal operation:Over load, Short-circuit, & Over heat |
Green mode function | 1% to 14% of full load |
(Auto-shut-off in blackout) | The default setting is OFF. |
Cooling fan control | Auto on / off, controlled by temperature & operation mode |
ENVORMENT AND SAFETY |
Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) |
Transit/storage Temp. | -15°C to 55(5°F to 131°F) |
Relative Humidity | 5 - 95% non condensing |
Operating Altitude | 0 ~ 3000 meters |
Quality control system | ISO 9001:2000, ISO 14002-2004 |
PHYSICAL |
Appearance | Size(mm)LxWxH | 580*315*300 |
G.W(Kg) | 1000W/19kg ;2000W/24kg ;3000W/28kg |
Size(mm)LxWxH | 755*319*288 |
G.W(Kg) | 4000W/38kg ;5000W/49kg ;6000W/49kg |
Payment & Shipping & Sample
1. Payment: T/T (Telegraphic transfer), and Western Union
2. Delivery time: 7 workdays for sample; 20-25 workdays for mass order
3. Shipping: DHL, FEDEX, UPS, EMS, Airway and By Sea
**Welcome Sample Order to test quality firstly**
Warranty :
Our product warranty is valid for 12 months after delivery. We undertake to repair any malfunctioned units due to defective components of inadequate workmanship ,but specially expecting any defects resulting from normal wear and tear of improper use of the products.
Guides and After-service Consultancy
Must Power Team will offer these guides below.
A. Need a Accessory
B. Products Repair
C. Power Problems to Solve
D. Power Protection Solutions, etc.
Want to know more about our Company, Products, Price, Packing, Shipping and any discount? Let's Inquiry with Ada NOW !!!!!
MUST Power Limited
HedY Huang
+86-151 18135723
Shenzhen Must Power Limited established in 2010, with the headquarter in Hongkong, which is a professional hi-tech enterprise specialized in UPS, Power Inverter, Solar Power, VRLA Battery development, manufacturing, sales and after-service.
Our comprehensive product lines include:
Off-line UPS, line interactive UPS, On-line UPS, Solar inverter, Power inverters, Stabilizers and Solar battery.
Most of products from MUST applied with CE, FCC certificates. The main markets are Ukraine, Russia, Vietnam, Thailand, Pakistan, India, etc. Must Power Limited is one of the authorized suppliers for China Citic Bank, Ministry of Information Industry of China, Ministry of Power Industry of China, Ministry of Transportations of China.
With an excellent R & D team formed by over 30 engineers and a skilled, dedicated workforce, together 10, 000 square meter in-house manufacturing facilities in Guangdong China, Shenzhen Must Power Limited has innovated, developed and improved the products to meet the demands of customers and keep pace with changing demands of the industries. With 'close to customer' notion, we have aligned most of its resources to support our Original Equipment Manufacturer (OEM) customers, and work with our customers as power partners. Our mission is to be the best supplier of power solutions, and to accomplish this, we will continue to tailor products for market needs while maintaining high quality, integrated customer service and prompt delivery.