Shanghai Vector Electronics Co., Ltd. >> Super Miniature Double Row Direct Plug Relay

Super Miniature Double Row Direct Plug Relay

Super Miniature Double Row Direct Plug Relay
Price: US $ 0.8089/Piece
Min Order: 1000/Piece
Pay Type: L/C,T/T,D/P,Western Union,Paypal
Prod Model: HFD2

Product Description

1.Characteristic
• bow into the SIEMENS D2 production line high sensitivity, coil power consumption, 150mW, Diallel standard elicited foot Lu using bifurcated contact forms, monostable and magnetic retention types available for environmental protection products (RoHS)
Dimensions: (20.2x10.2x10.6) mm

2
Contact parameters
Contact Form2Z
Contact resistance100MFi (10MA30Mvdc)
Contact materialRefer to the order mark
Contact Load (resistive)1A 125Vac, 2A 30Vdc 3A 30Vdc
Maximum switching voltage250Vac / 220Vdc
Maximum switching current3A
Maximum switching power125Va/90W
Minimum Application load (1)10Mv10|ja
Mechanical Durability1XTen8 Times
Electrical Durability (2)1XTen5 Times(1A 125Vac,
AgNContact, resistive load,0C,1SFlux9SBroken)
Note:(1) The minimum application load is a reference value. The reference value will be based on the breaking frequency, environmental conditions
Depending on the desired contact resistance and reliability, please confirm the test with the actual load before use.
 
(2) electrical durability is the data that is tested with a set of transformation contacts.
Insulation resistance1000M: (500Vdc)
Dielectric withstand pressureBetween the coil and the contact point1500Vac 1Min (Single coil) 1000Vac 1Min (Double coil)
 Between contacts and contact points1000Vac 1Min
Action Time(Rated voltage)^4.5Ms
Release time(Rated voltage)^3.5Ms
Action time (magnetic retention type)^4.5Ms
Reversion time (magnetic retention type)^4.5Ms
Temperature range-40 0C~ To0C
Humidity5%%rh
Vibration10Hz 55Hz 1.5Mm Double amplitude
 Stability490M/S2
/10 CityStrength980M/S2
Leads the wayPrinted panel(DIP)
WeightAbout 4.5G
Package modePlastic seal Type
Coil parameters
  Sensitive typeStandard type
Rated Coil PowerSingle Steady stateAbout 150MWAbout200MW
Single Coil Magnetic RetentionAbout 75MWAbout 100MW
 Double Coil Magnetic RetentionAbout 150MWAbout200MW
Coil temperature rise65K
Coil Specification Sheet 23°c
Single steady-state standard
 
Specifications
Code
Rated voltage VdcAction Voltage VdcRelease voltage VdcCoil resistor X(1:10%) QMaximum Voltage Vdc
003-M3<2.30^0.3456
005-M5<3.75^0.512510
006-M6<4.50^0.618012
009-M9<6.75^0.940518
012-M12<9.00^1.272024
015-M15<11.25^1.5112530
024-M24<18.0^2.4288048
048-M48<36.0^4.81152096
Single steady-state sensitive
Specifications
Code
Rated voltage VdcAction Voltage VdcRelease voltage VdcCoil resistor X(1 10%) QMaximum Voltage
Vdc
005-S5<4.0^0.516711.5
006-S6<4.8^0.624013.8
009-S9<7.2^0.954020.8
012-S12<9.6^1.296027.7
015-S15<12.0^1.5150034.6
024-S24<19.2^2.4384055.4
 
 
Specifications
Code
Coil Voltage VdcAction, reversion voltage VdcCoil resistor X(1:10%) QMaximum Voltage Vdc
003-M-L13<2.25908.4
005-M-L15<3.7525014
006-M-L16^4.536017
009-M-L19<6.7581025
012-M-L112<9.0144034
015-M-L115<11.25222042
024-M-L124<18.0400056
Single-line circle magnetic retention sensitive Type
 
Specifications
Code
Coil Voltage VdcAction, reversion voltage VdcCoil resistor X(1 10%) QMaximum Voltage Vdc
005-S-L15<4.033016
006-S-L16<4.848019
009-S-L19<7.2108029
012-S-L112<9.6192039
015-S-L115<12.0300043
024-S-L124<19.2768078
Note:(1) when the user has special requirements different from the above parameters, can negotiate an order;
(2) when the transistor-driven circuit voltage is5V, it is recommended to select4.5VSpecification Relays, 3VSelection of2.4VSpecifications relay.
 
Life times under typical contact load
Load VoltagePowerElectrical durability
Resistive loadInductive load (CommunicationCos0=0.7)
50Mvdc50^w5XTen7 Times5XTen7 Times
30Vdc20W3XTen6 Times1XTen6 Times
30Vdc30W1XTen6 Times3XTen5 Times
30Vdc60W1XTen5 Times1.5XTen4 Times
60Vdc20W3XTen6 Times--
60Vdc30W5XTen5 Times--
60Vdc60W1XTen5 Times--
30Vac40Va3XTen6 Times1XTen6 Times
30Vac80Va1XTen6 Times3XTen5 Times
30Vac120Va1XTen5 Times1.5XTen4 Times
60Vac40Va3XTen6 Times1XTen6 Times
60Vac80Va1XTen6 Times3XTen5 Times
60Vac120Va1XTen5 Times1.5XTen4 Times
125Vac40Va3XTen6 Times1XTen6 Times
125Vac80Va1XTen6 Times3XTen5 Times
125Vac125Va1XTen5 Times1.5XTen4 Times
23 0 C
 
Two-wire circle magnetic retention Standard
 
Specifications
Code
Coil Voltage VdcAction, reversion voltage VdcCoil resistor X(1:10%) QMaximum Voltage
Vdc
003-M-L23<2.25456
005-M-L25<3.7512510
006-M-L26<4.518012
009-M-L29<6.7540518
012-M-L212<9.072024
015-M-L215<11.25112530
024-M-L224<18.0204048
Dual-line Circle magnetic retention sensitive Type
 
Specifications
Code
Coil Voltage (Vdc)Action, reversion voltage VdcCoil resistor X(1 10%) QMaximum Voltage Vdc
003-S-L23<2.4606.9
005-S-L25<4.016711.5
006-S-L26<4.824013.8
009-S-L29<7.254020.8
012-S-L212<9.696027.7
015-S-L215<12.0150034.6
024-S-L224<19.2384055.4
Security certification
 
  0.5A 60Vdc 2A30Vdc
 Agpd/Agpd+Gilded1A120Vac
Ul/cul 2A125Vac 3A 30Vdc
 AgNi+Gilded/AgNi+Gilded2A30Vdc( 0C)
1A125Vac( 0C)
Note:(1) table does not indicate the temperature of the load, refers to ambient temperature for room temperature;
 
(2) The above list only part of the typical load of the product certification, the detailed test conditions for each load are different, so the number of electrical durability is not the same, if you need to know more details, please contact us.

Figure, wiring diagram, installation hole size
 

Contour map     Monostable and single coil magnetic retention
 
 

Contour map                             Double loop magnetic retention

Installation hole size
(bottom view)     Monostable and single coil magnetic retention
          
1C socket for DIP16
  Double loop magnetic retention
1C socket for DIP16
Wiring diagram
(bottom view)       Monostable and single coil magnetic retention
          
When the relay is magnetically maintained, it is shown to be a reset position.
"1" and "16" end excitation relay will move
"1" and "16" end reverse excitation relays will be returned
Double loop magnetic retention

The map is a reversion position
"1" and "16" end excitation relay will move
"2" and "15" end incentive relays will be returned
Note: (1) there is no dimension tolerance for the shape and size of the product. When the shape size is 1mm, the tolerance is + 0.2mm; when the shape size is between (1~5) mm, the tolerance is + 0.3mm; when the shape size is >5mm, the tolerance is + 0.4mm;
(2) the dimension tolerance in the size of the installation hole is + 0.1mm;
The grid width is 2.54mm.
Precautions: (1) the product is highly sensitive polarized relay. If the voltage polarity at both ends of the coil is not correct, the relay will not act.
(2) avoid using this relay in strong magnetic field. Strong magnetic field will cause changes in relay operation and release.
(3) the state of the magnetic maintenance relay is returned to the factory, but it may become an action state because of the impact of shock and other factors during the installation of the relay or relay, so when used (when the power is connected), please reset it to the state of return or action according to the need.
(4) the application of rated voltage to the coil is the basis for normal operation of the relay. Please confirm that the voltage applied to the coil of the relay reaches the rated voltage before use. For the magnetic maintenance relay, in order to ensure its action or return, the pulse width of the rated voltage applied to the coil must be more than 5 times that of the action or return time.
(5) for magnetic double coil relay, do not apply voltage to action coil and return coil simultaneously.
(6) the relay may be damaged when it falls or exceeds the impact condition.
(7) when the relay is loaded into the PCB plate welding, if the overall cleaning or surface treatment is required, please contact our department in order to agree on suitable welding conditions and suitable product specifications.
(8) for the plastic sealing products, after the welding is completed, the relay should be cooled naturally to less than 40 C, and then the cleaning and surface treatment should be carried out. The temperature of the cleaning solution and the surface treatment agent should be controlled below 40 C. When cleaning, avoid ultrasonic cleaning, avoid using gasoline, three chloroethane, freon, etc., which will have influence on the structure and environment of the relay.
 
 
Our company supplies different kinds of products. High quality and reasonable price. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with good quality at the reasonable price.