| Prod Model: |
GP33 series 10kva to 200kva |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Model: |
10-250kVA |
| Input Voltage: |
220V/380, 230/400, 240/415V |
| Frequency: |
50Hz/60Hz |
| Power Factor: |
0.8 |
| Floating Charge: |
405V/432V |
| Charge Current: |
1A-50A |
| Communication: |
RS232, Snmp, Dry-Contact |
| Display: |
LCD |
| Warranty: |
2 Years |
| Phase: |
Three Phase |
| Type: |
On-line |
| Protection: |
Overload, Short Circuit, Overcurrent, Overvoltage |
| Application: |
Telecommunication, Data Center, Banks |
| Classification: |
Low Frequency Online UPS |
| Standby Time: |
Long Backup Time(up to 12 Hrs) |
| Equipment Mode: |
Power Backup Solution |
| Brand: |
Zlpower |
Product Description
High Quality Online UPS Three Phase Online UPS
Low Frequency Online UPS
10KVA to 200KVA 8KW To 160KW LCD display
Main Features
*Intelligent inspect and monitor UPS systems every second
*The sixth generation IGBT inverter technology
*High definition touch screen LCD display and LED indicators, can show directly UPS status and operation, data records in table format, and events records.
*Adopts knock-down modular design, easy to maintain and save resources much; It is with new advanced turbofan which can release heat well and save energy; It also use non-circumfluence controlled circuit, can save electric much; GP33 UPS adopts green commute and inverter technology, ensure to provide clear energy for users; Its advanced digital circuit technology let whole UPS with 80% more life than before.
*Excellent load characters can fulfill with suddenly change load from 0 to 100%, and no need to invert to bypass, ensure output stable and reliable.
*Well-equipped protection function, including alarm function and excellent input and output under voltage overflow protection, input surge protection, phase failure protection, battery overcharge and over discharge protection, output overload short circuit protection, over heat protection and so on.
*Three phase can equal stable voltage and control separately, in order to control instantaneous overload degree of equal, realize output imbalance 100% load.
*Optional input harmonic filter or Twelve-pulse rectifier can restrain input harmonic pollution efficiently, improve UPS input power factor, and minish input harmonic current.
*Optional battery inspection module can test specification of every battery, and show on display. If battery faulty, will alarm immediately and inform administrators.
*Special set: can set UPS work status according to requirements of electric. User can choose from UPS operate mode, ECO save energy operate mode and EPS operate mode.
Application
Widely used in telecommunication,data center,banks,negotiable securities,traffic,arms,security,electronics,industry,large enterprises and so on.
Pictures



Any questions, pls feel free to contact Hiber | Model | GP3310 ~ GP33200 series Low Frequency Online UPS |
| Capacity (VA) | 10K | 15K | 20K | 30K | 40K | 60K | 80K | 100K | 120K | 160K | 200K |
| Noninal output capacity | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | 128KW | 160KW |
| Operate type | Double conversion low frequency online type |
| Input | voltage | 220V/380, 230/400, 240/415V, ±25% |
| Phase | Three phase +N+G |
| Frequency | 50Hz/60Hz±5% |
| Input power factor | 0.95(with input filter) |
| Soft start | 0-100% 5sec |
| Output | Voltage | 220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load) |
| Phase | Three phase +N+G |
| Frequency | 50/60Hz (1±5%, AC mode), 50/60Hz (±1%, Battery mode) |
| Power factor | 0.8 |
| Output wave | Pure sine wave |
| Distortion | Linear load <3%, non linear load<5% |
| Battery voltage | Standard battery voltage | 360V/384V |
| Floating charge | 405V/432V |
| Terminal voltage | 315V/336V |
| Charge current | 1A-50A (Can calculate and set according to battery configuration software) |
| Maximum discharge current | 28 | 42 | 56 | 85 | 113 | 169 | 225 | 282 | 338 | 381 | 507 |
| Main Function | Active voltage change | 0-100%±5% |
| Instant recover time | <10ms |
| Imbalance voltage | <±5%,<±1%( Balance load voltage) |
| Overload capacity | 125% → 10min,150% → 1min |
| Static switch | Automatic |
| Protection | UPS over current, short circuit, battery low voltage, over heat |
| Cold method | Compel aeration ( temperature control mode) |
| Noise | 60-65dB |
| Display | LED \ LCD display |
| Communication port(Optional) | RS232, SNMP, dry-contact |
| Alarm | Alarm with buzzer and indicators |
| Environment | Temperature: 0-40C Humidity: 0-90% |
| Net weight | kgs | 210 | 258 | 350 | 400 | 480 | 900 | 1100 | 1200 | 1250 | 1380 | 1520 |
| Size | L*W*H (mm) | 700×520×1100 | 800×600×1200 | 800×600×1500 | 1200×900×1600 | 2000×900×1800 |