| Prod Model: |
101 |
| Power Sourcing: |
110V/AC-240V/AC |
| Detection Distance: |
3~12m |
| Working Humidity: |
<93%Rh |
| <93%Rh: |
3-2000lux (Adjustable) |
| Time-Delay: |
Min.:10sec±3sec Max.:7min±2min |
| Rated Load: |
1200W (Incandescent Lamp) 300W (Energy-Saving Lamp |
| Type: |
Infrared Sensor Switch |
| Principle: |
Infrared |
| Wires: |
Two-Wires |
| Standard: |
Nonstandard |
| Application: |
Toilets |
| Certification: |
CE |
Product Description
Description
The product is a new saving-energy switch; it adopts good sensitivity detector, integrated circuit. SMT. It gathers automatism, convenience, safety, saving-energy and practicality functions. The wide detection field is consist of detectors. It works by receiving human motion infrared rays. When one enters the detection field, it can start the load at once and identify automatically day and night; Its installation is very convenient and Its using is very wide. It has functions of power indication and the detection indication.


Specification
Power Sourcing | 110V/AC-240V/AC |
Detection Range | 360° |
Detection Distance | 3~12m |
Working Humidity | <93%RH |
Ambient Light | 3-2000LUX (Adjustable) |
Time-Delay | Min.:10sec±3sec Max.:7min±2min |
Power Consumption | 0.45W (work) 0.1W (static) |
Installing Height | 2.2m~4m |
Detection motion speed | 0.6~1.5m/s |
Rated Load | 1200W (incandescent lamp) 300W (energy-saving lamp) |
FUNCTION
1.Can identify day and night: The consumer can adjust work ambient light. It can work in the daytime
and at night when it is adjusted on the "sun" position (max). It can work in the ambient light less than 3LUX when it is adjusted on the "moon" position (min). As for the adjustment pattern, please refer to the testing pattern.
2.SENS adjustable: It can be adjusted according to using location; low sensitivity with 3m for detection distance;high sensitivity with 6 or 12m, it fits for large room.
3.Time-Delay is added continually: When it receives the second induction signals after the first induction, it will compute time once more on the basic of the first time-delay rest.
4.Time-Delay is adjustable. It can be set according to the consumer's desire. The minimum time is 10sec±3sec. The maximum is 7min±2min.
INSTALLATIION (see the diagram)
1.Switch off the power.
2.Please moving the upper cover with anti-clockwise whirl as per the diagram in the crust.
3.Fix the bottom on the selected position with the inflated screw.
4.Connecting the power and the load to sensor as per the connection-wire sketch diagram.
5.Buttoning the upper cover on the sensor, whirling the cover with clockwise when LED light bare, then you could switch on the power and test it.
CONNECTION-WIER SKETCH DIAGRAM(see the right figure)
TEST
1.Turn the LUX knob clockwise on the maximum(sun),turn the TIME knob anti-clockwise on the minimum, turn the SENS knob clockwise on the maximum.
2.When you switch on the power, the controlled load and indication lamp are both not working. Preheat 30 seconds later, the load and the indicator lamp are turned on synchronization, in the absence of no inductor signals, the load should be stopped working within 5-30sec, the indicator lamp is turned off.
3.After the first is out, make it sense again after 5~10sec. The load should work. When there is no inductor signals in the indicator lamp, the load should be stopped working within 5-15sec.
4.Turn ambient light knob anti-clockwise on the minimum. If it is adjusted in the less than 3LUX, the inductor load should not work after load stop working. If you cover the detection window with the opaque objects (towel etc), the load work .under no induction
signal condition, the load should stop working within 5-15sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work!
NOTES
1.Electrician or experienced human can install it.
2.The unrest objects can't be regarded the installation basis-face.
3.In front of the detection window there shouldn't be hinder or unrest objects effecting detection.
4.Avoid installing it near air temperature alteration zones for example: air condition, central heating, etc.
5.For your safety. Please don't open the case if you find hitch after installation.
6.In order to avoid the unexpected damage of product, please add a safe device of 6A
when installing infrared sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
1.The load don't work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light do not turn on after sensing, please check if the working
light correspond to the ambient light.
d. Please check if the working voltage correspond to the power source.
2.The sensitivity is poor:
a. Please check if in front of the detection window there are hinder that effect to
receive the signals.
b. Please check the ambient temperature.
c. Please check if the signals source is in the detection fields.
d. Please check the installation height.
3.The sensor can't shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power correspond to the instruction.
d. If the air temperature change near the sensor, air condition or central heating etc.
Shipping And Payment Terms:
Delivery Time: 3-30 Days Based On Finally Order Quantities
Payment Terms: TT /L/C
Less Than 3000USD. 100% TT In Advance
More Than 3000USD, TT30% Deposite, The Balance See Copy Of B/L
Bigger Order: TT Or L/C
Our Service:
1. Your inquiry related to our products or prices will be replied in 24 hours.
2. Well-trained and experienced staffs to answer all your enquires in fluent English
3. OEM&ODM, any your customized product we can help you to design and produce
4. Distributorship are offered for your unique design and some our current models.
5. Protection of your sales area, ideas of design and all your private information.
6. All the products must through 24 hours aging before delivery to ensure the quality again.
How to contact?
| Contact Person | Mr. Jimmy Xie |
| Phone | 0086 138 68706510 |
| Fax | 0086-577-56848069 |
| Address | NO.218 Liule Rd,Liush,Town,Yueqing,Wenzhou,China |
Our company supplies different kinds of products. High quality and favorable price. We're pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with good quality at the reasonable price.
YUEQING SHUNTONG IMP&EXP Co., Ltd is one of subsidiary of SHUNTONG ELECTRIC Co., Ltd, focus on import and export business.
SHUNTONG ELECTRIC Co., Ltd is a large new technical professional manufactor on security products such as warning lights, siren, audible visual alarm, voltage stabilize & regulator and so on. It is one of the member of China Supply Institute, the member of professional institute of "Household AC automatic voltage regulator"
After so many years of developing and management, now Shuntong has become one of the best enterprises with quickly growing up in security field. The products are widely exported to over 50 countries. We hold a good share in market because of the good quality and services. We won a perfect reputation from users.
Shuntong staff insist on studying and trying to promote market based on technology and continue to innovate the service for society. We emphasize technical management for fast evelopment.