| Prod Model: |
T1K~T3KL |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Capacity: |
1kVA~3kVA |
| Nominal Voltage: |
110V, 120V/220V, 230V, 240V |
| Frequency Range: |
46~54Hz/56~64Hz |
| Input Power Factor: |
0.97 |
| Output Power Factor: |
0.7/0.8 |
| Wave Form: |
Pure Sine Wave |
| Current Crest Ratio: |
3:1 |
| AC Mode Efficiency: |
85% |
| Battery Mode Efficiency: |
83% |
| Communication Software: |
RS232 |
| Phase: |
Single Phase |
| Type: |
On-line |
| Protection: |
Short Circuit |
Product Description
This single phase high frequency online UPS T1K, T2K, T3K is double conversion uninterruptible power supply,
pure sine wave output wave form. It is divided into two models, one is standard online UPS with inside batteries,
the other is long backup time online UPS without batteries.
Application:
Servers, computer data center, critical network devices, sensitive electronic equipment, telecom, smaller lans,
workstation, IPC, small medical equipment, key devices, communication system, some devices need electric power environment.
Main Features:
1. LED Indicators display Detailed Real-Time UPS Status and UPS fault.
2. Advanced MCU microprocessor control technology, ensure long life reliability. 3. Wide input voltage range, Zero transfer time.
4. Excellent Protection against over voltage, over load, over current, over charge and so on.
5. Input L and N lines reverse wiring detection, Auto start when AC back.
6. DC start function, Input PFC revise function.
7. Humanization bypass output can be adjustable.
9. Smart RS232 communication with monitoring software.
10. Intelligent slot available for AS-400 Dry contact and SNMP card Remote control.
11. Strong antijamming capability.
12. Available to work with generators.
13. Lightning, surge, short circuit, Network/fax/modem surge protection.
| Online UPS MODEL | T1K | T2K | T3K | T1KL | T2KL | T3KL |
| CAPACITY | VA/W | 1000VA /700W | 2000VA /1400W | 3000VA /2100W | 1000VA /700W | 2000VA /1400W | 3000VA /2100W |
| INPUT | Nominal Voltage | 110/115/120VAC or 220/230/240VAC |
| Voltage Range | 60~138VAC or 115~300VAC |
| Frequency Range | 50Hz: 46~54Hz; 60Hz: 56~64Hz |
| Phase | Single phase with Ground |
| Power Factor | >=0.97 |
| OUTPUT | Voltage | 110/115/120*(1±2%)VAC or 220/230/240*(1±2%)VAC |
| Frequency | 50/60Hz(Adjustable 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1±0.2%) 60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%) |
| Wave Form | Pure Sine Wave |
| Power Factor | 0.7 |
| Harmonic Distortion | <3% THD (Linear Load), <7% THD (Non-Linear Load) |
| Overload Capacity | 110%~150% maintain 30s then turn to bypass output, over 150% maintain 200ms |
| Current Crest Ratio | 3:1 |
| Connections | IEC320*4 | IEC320*6 | IEC320*3 & Terminal block | IEC320*4 | IEC320*6 | IEC320*3 & Terminal block |
| Efficiency | To AC Mode | 85% |
| To Battery Mode | 83% |
| Battery | Type | Sealed free maintenance lead acid battery |
| Nominal DC voltage | Built in batteries 12v7.2ah | 36VDC | 96VDC | 96VDC |
| Quantity | 3pcs | 8pcs | 8pcs | Depends on requested back-up time |
| Back-up Time (Full load) | >=7 minutes | >=8 minutes | >=6 minutes | Depends on the capacity of external battery bank |
| Recharge Time | 5hours to 90% of capacity full discharge | Depends on the capacity of external battery bank |
| Charge current(MAX) | 1.0A | 1.0A | 1.0A | 7A | 8A | 8A |
| Charge voltage | 41.1Vdc ± 0.6V | 110Vdc ± 0.4V | 41.1Vdc ± 0.6V | 110Vdc ± 0.4V |
| Bypass | Automatic Transfer | On overload and UPS failure |
| Before UPS Power-on | Default "NO" user adjustable to "YES" |
| Transfer Time | | 0ms, less than 4ms from inverter to bypass and vice versa |
| Indicators | LCD Display | UPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault code |
| Audible Alarm | | Bypass, On battery mode, Battery low, Overload, Fault |
| Acoustic noise | At 1 meter distance | <45dB | <50dB | <50dB | <45dB | <50dB | <50dB |
| Communications | Intelligent RS232 serial port | Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX and MAC |
| SNMP (Optional) | Remote control UPS through SNMP management and Internet |
| USB (Optional) | Windows family software and Mac OS |
| Network Surge Protection | | RJ45 I/O port available for network or FAX/Telephone line/Modem |
| Environmental | Operating Temperature | 0~40centi-degree |
| Operating Humidity | 20~90% ( Non Condensing) |
| Weight | Net weight (kg) | 14 | 31.5 | 32 | 7 | 13.5 | 14 |
| UPS Dimension | L*W*H (mm) | 400*145*220 | 460*192*348 | 460*192*348 | 400*145*220 | 460*192*348 | 460*192*348 |