Aerospace Electric Group Co., Ltd. >> 450/750V Copper Core PVC Insulated Electric Wire

450/750V Copper Core PVC Insulated Electric Wire

450/750V Copper Core PVC Insulated Electric Wire
Price: US $ 1-50/Meter
Min Order: 100/Meter
Pay Type: L/C,T/T,D/P
Prod Model: BV/RV/BVR/BVV
Color: Black,Red,Yellow,Blue,White
Type: Insulated
Conductor Type: Solid
Insulation Material: PVC
Certification: CCC
Application: Electrical Device/Domestic Appliance,etc
Sheath Material: None
Range Of Application: Electrical Device/Domestic Appliance,etc
Brand: Zhonghua

Product Description

450/750V Copper Core PVC Insulated Electric Wire 

Application 
A. It can be applied to be installation and connection for electrical device, equipment power device, domestic appliance, instrument,lighting circuit, and automation device.
B. The feature of flame retardant cable is not easy to be fired and can control the flame into certain restriction and slow the fire speed after fire. So it can be applied to the occasion with high request of  flame retardant.
C. Flame cable can be divided into 4 grade: A,B,C,D and the Grade A is the best flame retardant grade.
D. Beside the cable can transfer power at the normal condition, it can also keep a period of safe operation under fire. It can be applied for the occasion with request of fire resistance.


Pruduct Structure



Reference Data of the Product Structure:  IEC 60227
1. 01(BV)Cable
Nominal Section
of the conductor
(mm2)
Conductor TypesCable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(/km)
Minumum Insulation Resistance at 70ºC
(M·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
BVMinimumMaximumBV
1.512.822.63.219.7012.10.01118
1.523.002.73.320.3112.10.01018
2.513.433.23.931.207.410.01025
2.523.693.34.032.827.410.00925
413.903.64.446.084.610.008533
424.203.84.647.454.610.007733
614.414.15.065.713.080.007042
624.774.35.267.193.080.006542
1015.655.36.4109.091.830.007058
1026.135.66.7113.071.830.006558
1627.186.47.8170.901.150.005078
2528.928.19.7268.520.7270.0050105
35210.069.010.9362.820.5240.0043130
50211.8110.612.8492.150.3870.0043155
70213.6112.114.6694.190.2680.0035200
95215.9314.117.1959.230.1930.0035250
120217.5415.618.81197.150.1530.0032290
150219.4917.320.91472.950.1240.0032335
185221.8019.323.31846.140.09910.0032390
240224.8322.026.62416.540.07540.0032470
300227.6724.529.63023.550.06010.0030540
400231.0627.533.23851.720.04700.0028635
 
2.02(RV)Cable
Nominal Section
of the conductor
(mm2)
Conductor TypesCable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
RVMinimumMaximumRV
1.553.002.83.420.3013.30.01018
2.553.643.44.131.597.980.00925
454.213.94.847.544.950.007033
654.814.45.367.423.30.006042
1056.285.76.8118.001.810.005658
1657.206.78.1169.441.210.004678
25510.108.410.2269.710.780.0044105
35511.239.711.7364.350.5540.0038130
50513.7511.513.9522.860.3860.0037155
70515.4013.216.0720.890.2720.0032200
95518.1515.118.2953.890.2060.0032250
120519.7016.720.21199.280.1610.0029290
150521.1018.622.51485.620.1290.0029335
185524.0320.624.91824.520.1060.0029390
240526.7023.528.42389.690.08010.0028470
 
3.05(BV)Cable
Nominal Section
of the conductor
(mm2)
Conductor TypesCable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)

Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
BVMinimumMaximumBV
0.512.041.92.38.1636.00.0159
0.7512.212.12.510.7124.50.01212
112.372.22.713.4818.10.01114
 
4.06(RV)Cable
Nominal Section
of the conductor
(mm2)
Conductor TypesCable Reference Diameter
(mm)
Cable Average Diameter
(mm)

Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
RVMinimumMaximumRV
0.552.182.12.58.5839.00.0139
0.7552.432.22.711.5026.00.01112
152.522.42.814.0019.50.01014
 
5.10(BVV)Cable
Core No.×Nominal Section
of the conductor
(mm2)

Conductor Types
Cable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
BVVMinimumMaximumBVV
2×1.519.367.610.098.9412.10.01118
2×1.529.727.810.5103.0912.10.01018
2×2.5110.568.611.5130.997.410.01025
2×2.5211.089.012.0138.557.410.00925
2×4111.509.612.5171.314.610.008533
2×4212.1010.013.0179.244.610.007733
2×6112.5210.513.5218.413.080.007042
2×6213.2411.014.0227.773.080.006542
2×10115.6413.016.5361.551.830.007065
2×10216.7013.517.5384.711.830.006565
2×16218.8015.520.0532.011.150.005287
2×25222.6418.524.0798.610.7270.0050110
2×35225.7221.027.51055.970.5240.0044140
3×1.519.88.010.5124.6112.10.01115
3×1.5210.198.211.0129.7112.10.01015
3×2.5111.109.212.0168.947.410.01021
3×2.5211.669.412.5178.677.410.00921
3×4112.1210.013.0228.204.610.008528
3×4212.7610.513.5238.214.610.007728
3×6113.6211.514.5307.473.080.007036
3×6214.4012.015.5319.963.080.006536
3×10116.5214.017.5476.741.830.007056
3×10217.6714.519.0507.401.830.006556
3×16220.3416.521.5726.411.150.005274
3×25224.0520.526.01074.220.7270.005098
3×35227.3122.029.01431.170.5240.0044120
4×1.5110.518.611.5159.4312.10.01115
4×1.5210.959.012.0165.6212.10.01015
4×2.5111.9610.013.0216.487.410.01021
4×2.5212.5910.013.5228.557.410.00921
4×4113.4911.514.4296.504.610.008528
4×4214.2212.015.0309.464.610.007728
4×6115.1312.516.0398.923.080.007036
4×6215.9913.017.0414.943.080.006536
4×10117.9315.519.0594.971.830.007056
4×10219.2016.020.5633.591.830.006556
4×16222.1418.035.5916.621.150.005274
4×25227.0922.528.51414.080.7270.005098
4×35228.8424.532.01826.390.5240.0044120
5×1.5111.319.412.0191.0812.10.01115
5×1.5211.799.812.5198.3912.10.01015
5×2.5112.9311.014.0260.977.410.01021
5×2.5213.6311.014.5275.467.410.00921
5×4115.0012.516.0370.964.610.008528
5×4215.8113.017.0387.084.610.007728
5×6116.3713.517.5482.443.080.007036
5×6217.3414.518.5501.423.080.006536
5×10119.5017.021.0725.111.830.007056
5×10220.9417.522.0771.841.830.006556
5×16224.5720.526.01142.091.150.005274
5×25229.6124.531,51732.020.7270.005098
5×35233.0927.035.02272.060.5240.0044120
Notes: Conductor Types--1st type is solid conductor;2nd type is stranded conductor;5th type is stranded soft conductor;
      which are suitable for different applications.




 
Aerospace Electric Group Co., Ltd (AEG for short), formerly known as Wuhan Cable Group Co., Ltd., is an state-owned enterprise subsidiary to the 9th Research Institute of China Aerospace Science and Technology Corporation (CASC). Specialized in manufacturing and R&D of excellent quality electric wires & cables with over 60 years' professional experience, AEG now integrates Conductor Business Division, Power Cable Business Division, International trade Division, Aerospace Rich Special Cable Co., Ltd, Hubei Aerospace Cable Co., Ltd and Hubei Longsky Communication Technology Co., Ltd. Now AEG has 2080 employees, including 300 senior professionals. The total asset of the group has reached 3.85billion RMB.

AEG imports a series of advanced production and testing equipment from Germany, the United States, Britain, Italy, etc., which helps to achieve the production capability of 30, 000 tons of aluminum alloy conductors, 80, 000 tons of aluminum conductor steel-reinforced(ACSR), 24, 000 tons of aluminum-clad steel wires, 30, 000 km. Of LV and MV cables and 50, 000 km. Of special cables and wires. The overall production scale reaches 5 billion RMB.

Products of AEG are applicable to power production, power supply, construction and installation etc., We supplied for Daya Bay Nuclear Power Plant, Three Gorges Hydroelectric Power Station, Datang Power Plant, Wuhan Tianhe International Airport, Guangzhou---Wuhan Express Railway, Daqing Oil Field, Tiananmen Square reconstruction, Wuhan Metro, etc. The military-related products are used by Xichang Satellite Base, Chengdu Airport, the 2ND Artillery Corps, Dongfeng Motor, Naval Base and other large scale nationally focused engineering construction. They are also exported to more than 20 countries and regions including USA, Germany, Greece and Pakistan. Many products are granted with national, ministerial, provincial and municipal Excellent New Product Award and Prize for Progress in Science and Technology while others obtain national utility model patents.

We're pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.

Send your message to this manufacturer

More >

Other Products with This Manufacturers