Zhengzhou Jinyuan Wire and Cable Co., Ltd. >> 4X95+50mm2 Copper XLPE Insulated PVC Sheath Electrical Power Cable

4X95+50mm2 Copper XLPE Insulated PVC Sheath Electrical Power Cable

4X95+50mm2 Copper XLPE Insulated PVC Sheath Electrical Power Cable
Price: US $ 6.3/Meter
Trade Terms: FOB,CFR,CIF
Min Order: 1000/Meter
Pay Type: L/C,T/T,D/P
Prod Model: 4x50+25mm 2
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
Color: Black
Certificate: Ce, ISO 9001
Application: Power Station
Current: DC Cable
Insulation Material: PVC
Certification: CE
Voltage: 1kv
Brand: Jytop

Product Description

0.6/1KV, Mult core, Copper conductor, XLPE or PVC insulated and PVC or PE sheath cables.

CONSTRUCTION: CU/XLPE/PVC or PE

Operation characteristic
 The maximum operating temperature of cores shall not exceed 90ºC ween the cable used for a long period. The temperature of cores shall not exceed 250ºC at short circuit for 5 seconds. The ambient temperature should not be below 0ºC during installation.
   The permissible bending radius for cable should be the permissible bending radius for cable shall be complied with the regulation as below:
For single-core No armoured cable: R>20(D+d)±5% For multi-core:R>15(D+d)±5%
            Armoured cable:R>15(D+d)±5% For multi-core:R>12(D+d)±5%
Where:R-being radius(mm) D--overall diameter of the cable(mm)
      d-diameter of conductor(mm)
The single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducts.  
 
Main Technical Properties
Rated voltage of cable0.6/1(1.2)KV
D.C. Resistance of conductorAccording to GB/T3956-2008 or IEC 60228-2004
Power frequency withstand voltage test for 5 minutesNo breakdown at 3.5 KV
Hot set test for insulation,200ºC 15 min with pressure 20N/cm2  
Load elongation
≤175%
Max permanent elongation after cooled≤15%

 
Installation and operation condition of cable
 
In air:
1. The single-core cables are parallel laid,the distance between the cable center is 2 times of the cable diameter for cross-section area of conductor≤185mm² and 90mm for cross sectional area of conductor ≥240mm²
2. Ambient air temperature:40ºC
3. Max.Continuous  operating temperature of conductor:70ºC


Current rating factors for variation in ambient air temperature
Ambient air temperature20ºC25ºC30ºC35ºC40ºC45ºC
Rating factor1.291.221.151.081.00.91

Direct in the ground:
1. The single-core cables are installed separately,the distance between the cable center is 2 times of cable diameter.
2. Soil temperature:25ºC
3. Max. Continuous operating temperature of conductor:70ºC
4. Thermal resist of soil:1.0ºC.m/W
5. Depth of laying:0.7m
 
Current rating for variation in soil temperature
Soil temperature20ºC25ºC30ºC35ºC40ºC
Rating factor1.041.00.960.920.87


Main technical data :
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
 
 
Cable size
 
Conductor type
Nominal thickness of XLPE insulation(mm)Nominal thickness of PVC or PE sheath(mm)Approx. cable overall diameter (mm)Max. D.C resistance @ 20 0 C  (Ω/km)
Phase
core
Earth
core
Phase
core
Earth
core
Phase
core
Earth
core
4x2.5+1.5mm 2RERE0.70.71.812.27.4112.1
4x4+2.5mm 2RERE0.70.71.813.44.617.41
4x6+4mm 2RERE0.70.71.814.73.084.61
4x10+6mm 2RMRE0.70.71.817.81.833.08
4x16+10mm 2RMRM0.70.71.830.81.151.83
4x25+16mm 2SMRM0.90.71.823.20.7271.15
4x35+16mm 2SMRM0.90.71.825.10.5241.15
4x50+25mm 2SMSM1.00.91.928.60.3870.727
4x70+35mm 2SMSM1.10.92.132.80.2680.524
4x95+50mm 2SMSM1.11.02.237.40.1930.387
4x120+70mm 2SMSM1.21.12.441.40.1530.268
4x150+70mm 2SMSM1.41.12.545.20.1240.268
4x185+95mm 2SMSM1.61.12.750.70.09910.193
4x240+120mm 2SMSM1.71.22.956.80.07540.153
4x300+150mm 2SMSM1.81.43.162.80.06010.124
Zhengzhou JINYUAN Wire and Cable Co., Ltd, as a professional cable manufacturer. We have get ISO9001 and CE certificates. Our Professional and complete cable solutions make JYTOP Cables become to the partner of choice for international companies around the world,

PRODUCTS & STANDARDS & International Market:

1). Bare Conductor:

All Aluminum Conductor (AAC),

All Aluminum Alloy Conductor (AAAC),

Aluminum Conductor Steel Reinforced (ACSR),

Aluminum Alloy Conductor Steel Reinforced (AACSR),

Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW),

Aluminum Conductor Aluminum Alloy Reinforced (ACAR),

Aluminum Conductor Steel Supported (ACSS),

Aluminum Conductor Aluminum Coated Steel Reinforced (ACSR/AW)

All Copper Conductors(ACC),

Aluminum Coated Steel Wire(ACS),

Copper Coated Steel Wire(CCS),

Copper Coated Aluminum(CCA),

Galvanized Steel Wire(GSW),

Enameled Wire - Enameled round Aluminum Wire & Enameled round copper Wire

2). Overhead Cable:

Aerial Bundled Cable (ABC).

XLPE Cable,

Flexible Cable,

Single Core Cable,

2 Core Cable,

3 Core Cable,

4 Core Cable.

3). Building wire and cable:

THHN /THWN Cable

TW/THW Cable

PVC Insulated Wire,

XLPE Insulated cable.

4. Power Cable:

Armored /Non-armored Power cable

AWA Cable

SWA Cable

Standards: IEC, ASTM, AS/NZ, SANS, BS, DIN, NF, JISC, etc.

We can meet customers' special requirements, and provided OEM service.

Mainly Oversea Marketing: Southeast Asia, The Middle East, Africa, South America, so on.

We will be recognized as a professional Manufacturer in cable industry, through continuous improvement of our product quality, after sales service. We can give you the reliable solution for cable wires.

Company website: www.jytopcable.com

Send your message to this manufacturer

More >

Other Products with This Manufacturers