6kv/11kv/27kv/38kv 50Hz/60Hz Natural Grounding Resistor for Transformer or Grnerator
| Price: |
US $ 20000/Piece |
| Min Order: |
1/Piece |
| Pay Type: |
L/C,T/T,D/P |
| Prod Model: |
NGR |
| Application: |
Power |
| Phase: |
Three |
Product Description
NGRGENERATOR MIDDLE POINT RESISTOR PANEL 1.TECHABICAL DATAWHEN THE GENERATORS LOOP HAPPEN THE SINGLE EARTHING,THE CURRENT WILL BE BIGGER THAN THE RATED CURRENT ,IT WILL MAKE THE EARTHING OVER VOLTAGE IN ARC LIGHITNG,FOR THE IT IS LOWER LEVEL OF GENERATOR 'S WITHSTAND VOLTAGE,INSULATION WILL TO BE EASY TO BE SHATTERED.IF IT MAKE OVER CURRENT OF EARTHING,THE GENERATOR 'S CORE WILL BE BURNED AND SINTERED. IT IS USUALLY TO SET THE MIDDLE POINT TO EARTH BY HIGH VOLTAGE RESISTOR TO LIMITE THE ARC LIGHT OVER VOLTAGE,AND TO LOMITED THE CORE OF THE GENERATOR TO BE BURNED AND SINTERED,IN THE SAME TIME,IT WILL IMPORVE THE DELICACY DEGREE OF THE RELAY PROTECTION,EFFECTIVE TO THE TRIP TO MAKE THE LIMITED OF 2.6TIMES OF THE VOLTAGE BETWEEN PHASESES FOR THE OVER VOLTAGE TO LIMIT THE ARC TO BE REBURNED
,AND TO PROTECT THE MAIN INSTRUMENTS AND LIMITE THE CORE MAGNETISM SYNTONY OVER VOLTAGE,FOR SAFETY RUNING OPF THE GENETATOR. 2,PRODUCTS CHARACTERISTIC1, THE PRODUCTS IS MADE OF EXCELLENT STAINLESS STEEL (Cr20Ni80) OR NON METAL(CHAR COAL VALVE,ZINC VALVE)MAERIAL,IT IS HIGH COINDUCTANCE,HIGH TEMPERATURE COEFFICIENT ,UP TO WITHSTAND 1600ºC,BE ANTI CORRUPTED,GOOD TENACITY,NO CHANGE SHAPE,GOOD STABITITY.2,THE TRAN SORMER IS DRY TRNAS FORME IN PANBEL,BIG CAPACITOR,HIGH WITHSTAND IMPULSION.3,REISITOR PANEL IS IN DOOR ,THE BOX IS MADE OF COOL ROLLING STEEL .4,IT CAN ADD THE ERATHIGN RECORDER AND TEMEPERTURER ANDHUMID COTOLLER,3,CONDITION1,INDOOR,IF OUTDOOR ,PLEASE NOTED.2,ALTITUDE IS NO MORE 4000M,HIGH ALTIPLANO,PLEASE TELLUS THEALTITUDE .3,ENTIRONMENT TEMPERATURE:-20ºC~+70ºC,RELATIVE HUMIDITY NO MORE IS 95%4,AMBIENCE IS WITHOUT BURNING AND BROKE AND CAUSITICITYGAS OR TRANSMIT ELECTRICITY DUST.5,IT IS USED FOR 48~52Hz(50 Hz),58~62 Hz(60 Hz)SYSTEM.
4,TECHANICAL DATA6.1 NGR GENERATOR NATURE POIND REISISTOR PANAL TECHANICAL DATAGENERATOR CAPACITOR (MW) | 100/125 | 200 | 300 | 600 | 900/1000 |
| GENERATOR RATED VOLTAGE(kV) | 10.5 | 13.8 | 15.75 | 18 | 20 | 20 | 24 | 24 | 27 |
| EXPECED LOOP SINGLE EATHING MAX CAPACITOR CURRENT(A) | 4 | 5 | 6 | 8 | 10 |
| EARTHIHG TRANSFORMER FIRST VOLTAGE(kV) | 10.5/ | 13.8/ | 15.75/ | 18/ | 20/ | 20/ | 24/ | 24/ | 27/ |
| EARTHING TRANSFORMER SECOND VOLTAGEkV) | 0.22 | 0.22 | 0.22 | 0.22 | 0.22 |
| EARTHING TRANSFORMER CAPACITOR(kVA) | 30 | 30 | 50 | 50 | 63 |
| SECOND SIDE RESISTANCE(Ω) | 1.0 | 0.8 | 0.5 | 0.4 | 0.3 |
EARTHING PROTECTIVE SIMPLE VOLTAGE (kV) | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |

Ningbo Hyuan Power Industry Co., Ltd was found in 2006, It is a professional company which is involved in Complete supply, Designing, Consulate and Service of Substation up to 245kv and of Distribution Automation up to 245kv
Our product is including of:
1.15KV/27KV/38KV, 50Hz/60Hz, 630A/1250A The Most advanced Recloser in the world for Pole mounted and Substation Mounted with Protocol IEC61850/DNP3.0 according to IEEE/ANSI/IEC standard;
2.15KV/27KV/33KV/66KV/123KV/145KV/150KV/170KV/245KV, 50Hz/60Hz, 1250A/2000A/3150A, Three phase Outdoor Isolator/Disconnector with Double Break at side /Central Single Break for Level/Vertical Mounted on Pad Substation or Power Tower;
3.15KV/27KV/33KV/66KV/123KV/145KV/150KV/170KV/245KV, 50Hz/60Hz, 1250A/2000A/3150A, Outdoor Three phase /Single phase SF6/Vacuum Circuit Breaker with Three Phase Common Operation /Single Phase Seperate Operation;
4.15KV/27KV/38KV/66KV/123KV/145KV/150KV/245KV, 50Hz/60Hz, MR2000/1(5)A, Outdoor Oil/Resin/Capacitor Current transformer, Voltage Transformer up to 5 cores;
5.15KV/27KV/38KV/66KV/123KV/145KV/150KV/245KV, 50Hz/60Hz, 100kvar to 100Mvar capacitor bank for pad mounted and Pole mounted;
6.15KV/27KV/38KV/66KV/123KV/145KV/150KV/245KV, 50Hz/60Hz Power Transformer up to 200mva and reactor up to 200Mvar;
7.400V/6KV/15KV/27KV/38KV, 50Hz. 60Hz, indoor AC control and Protection switchgear panel for substation and Distribution system;
8.48VDC/110VDC/220VDC 50Hz/60Hz Lead-Acid/Ni-CD Battery bank with Charger up to 2000AH;
9.15KV/27KV/38KV/66KV/123KV/145KV/150KV/245KV, 50Hz/60Hz Cable heat srink/cold shrink Terminal and Joint with joint box
10.33KV/66KV/145KV 50Hz/60Hz dead tank GCB /HGIS and compact GIS;
11.11KV/33KV, 50Hz/60Hz, 9/11/17/32 steps ON LOAD TAP CHANGER for Power Ttansformer
12. RTU remote terminal unit for VCB, SWITCHGEAR AND RECLOSER WITH IEC61850/DNP3.0 Protocol
Our Mian service is including of:
1. Designing, Complete Supply, Conssate and Commission of 33KV/66KV/145KV/245KV 60Hz/50Hz substation including of GCB, DS, CT PT, LA, Transformer, Cable, Control & Protection Panel, Earthing Grounding system,
SCADA system, Steel grid tower;
2. Desinging, Complete Supply, consulate and Commission of 33kv/66kv/145kv/230kv 60Hz/50Hz Distribution automatic system including of recloser, sectionaliser, fault indicator, RTU, GPRS, and management software
We are rich experience in substation and automatic distribution system for 10years, our business had been involve in the world I including of Bangladesh, Indonesia, malasia, Pakistan, zimbia, zembewei, Peru, Ecuador ect over the world.
Customerizer will be welcome, Speciall required wil be welcome, we have good experience to proposal you and support you to success in business.
All the goods from HEMG will be guaranteed within 2 years, in specially, it will be 5 years.
For Above 1 million Order, We will send our engineer to work in site untill runing in good conditions.
More >
Other Products with This Manufacturers