BS 6724 SWA Armoured LSZH Sheath 0.6/1kV LV Power Armour Cable

1. Overview
Low Voltage Power Cables, Aluminum and Copper conductors of voltage range:0.6/1.0 kV.

2. Cable Types
Copper Conductor Cables
Aluminium Conductor Cables
Thermoplastic/ PVC Insulated Cables
Thermoset/XLPE Insulated Cables
Armoured/ Non - Armoured Cables
Single core cables up to and including 1000 mm2
2 core cables up to and including 95 mm2
3, 4 core & 4 core with reduced neutral cables up to and including 500 mm2

3. Applicable Standards
IEC 60502 (Part 1)"PVC/ XLPE insulated cables" single core /multi-core BS 5467 for XLPE insulated Armoured cables
BS 7889 for XLPE insulated single core unarmoured cables


4. Cables Include:
4.1 BS 6724 SWA LSZH 0.6/1kV Cable
4.1.1 Cable construction
ConductorClass 2 stranded copper conductor according to BS EN 60228
InsulationXLPE (Cross-Linked Polyethylene)
BeddingLSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655
ArmourSWA (Steel Wire Armour)
SheathLSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655

4.1.2 Electrical Characteristics
Dimensions - BS6724 XLPE/LSZH/SWA/LSZH (Copper)
No. of CoresNominal Cross Sectional AreaNominal Thickness of InsulationNominal Overall Diameter mmNominal Weight
mm²mmUnder ArmourOverallkg/km
21.50.67.312.1302
22.50.78.513.6346
240.79.414.7410
260.710.515.9499
2100.712.318648
2160.714.320.4978
2250.914.720.41290
2350.916.823.31500
25011925.81890
2701.122292450
2951.125.133.13300
21201.227.936.14020
21501.430.939.34750
31,50.67.812.6330
32.50.79.214.1390
340.71015.3464
360.711.216.6568
3100.713.119.5866
3160.715.321.61152
3250.918.923.61800
3350.921.325.72230
350121.728.52490
3701.125.232.23290
3951.128.8374440
31201.23240.45470
31501.435.945.56930
31851.64049.88350
32401.744.955.110400
33001.849.860.212600
3400255.866.614600
41.50.68.513.3365
42.50.79.915438
440.71116.4532
460.712.318.7764
4100.714.521.11013
4160.71723.41360
4250.92126.12160
4350.923.628.62690
450125323130
4701.129.537.74500
4951.133.341.75600
41201.237.547.17400
41501.441.651.48780
41851.646.456.610630
42401.752.66313390
43001.85868.816290
4400265.478.119800
51.50.69.714.3410
52.50.711.716.1470
540.71317.8710
560.714.520876
5100.717.222.91165
5160.72026.61742
5250.924.731.52323
5350.927.834.82932
550132.440.44192
71.50.610.215.2470
72.50.712.317.1600
740.713.619.1881
121.50.613.719.4780
122.50.716.322.41000
191.50.616.222.21000
192.50.719.926.61540
271.50.62026.71500
272.50.72430.71950
371.50.622.3291800
372.50.726.933.82350

Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross 
Sectional Area
Minimum No. Of Wires In ConductorMaximum Resistance 
of Conductor At 20ºC
mm²CircularCircular CompactedShapedAnnealed Copper Conductor
CuAlCuAlCuAlPlain Wires ohms/km
1.57-6---12.1
2.57-6---7.41
47-6---4.61
67-6---3.08
107766--1.83
167766--1.15
257766660.727
357766660.524
50191966660.387
701919121212120.268
951919151515150.193
1203737181518150.153
1503737181518150.124
1853737303030300.0991
2403737343034300.0754



4.2 BS 5467 SWA PVC 0.6/1kV Cable
4.2.1 Cable Construction:
ConductorClass 2 stranded copper conductor according to BS EN 60228
InsulationXLPE (Cross-Linked Polyethylene)
BeddingPVC (Polyvinyl Chloride)
ArmourSWA (Steel Wire Armour)
SheathPVC (Polyvinyl Chloride)

4.2.2 Electrical Characteristics
Dimensions - BS5467 XLPE/PVC/AWA/PVC (Copper)
No. of CoresNominal Cross Sectional AreaNominal Thickness of InsulationNominal Overall Diameter mmNominal Weight
mm²mmUnder ArmourOverallkg/km
21.50.67.312.1302
22.50.78.513.6346
240.79.414.7410
260.710.515.9499
2100.712.318648
2160.714.320.4978
2250.914.720.41290
2350.916.823.31500
25011925.81890
2701.122292450
2951.125.133.13300
21201.227.936.14020
21501.430.939.34750
31,50.67.812.6330
32.50.79.214.1390
340.71015.3464
360.711.216.6568
3100.713.119.5866
3160.715.321.61152
3250.918.923.61800
3350.921.325.72230
350121.728.52490
3701.125.232.23290
3951.128.8374440
31201.23240.45470
31501.435.945.56930
31851.64049.88350
32401.744.955.110400
33001.849.860.212600
3400255.866.614600
41.50.68.513.3365
42.50.79.915438
440.71116.4532
460.712.318.7764
4100.714.521.11013
4160.71723.41360
4250.92126.12160
4350.923.628.62690
450125323130
4701.129.537.74500
4951.133.341.75600
41201.237.547.17400
41501.441.651.48780
41851.646.456.610630
42401.752.66313390
43001.85868.816290
4400265.478.119800
51.50.69.714.3410
52.50.711.716.1470
540.71317.8710
560.714.520876
5100.717.222.91165
5160.72026.61742
5250.924.731.52323
5350.927.834.82932
550132.440.44192
71.50.610.215.2470
72.50.712.317.1600
740.713.619.1881
121.50.613.719.4780
122.50.716.322.41000
191.50.616.222.21000
192.50.719.926.61540
271.50.62026.71500
272.50.72430.71950
371.50.622.3291800
372.50.726.933.82350

Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross 
Sectional Area
Minimum No. Of Wires In ConductorMaximum Resistance 
of Conductor At 20ºC
mm²CircularCircular CompactedShapedAnnealed Copper Conductor
CuAlCuAlCuAlPlain Wires ohms/km
1.57-6---12.1
2.57-6---7.41
47-6---4.61
67-6---3.08
107766--1.83
167766--1.15
257766660.727
357766660.524
50191966660.387
701919121212120.268
951919151515150.193
1203737181518150.153
1503737181518150.124
1853737303030300.0991
2403737343034300.0754
3006161343034300.0601
4006161535353530.047
Notes
1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC , the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables must be used.

For more information, don't hesitate to call us on +86-15838290725 or send inquiry to me.

Henan Hongda Cable Co., Ltd. Located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Our company covers an area of 100, 000 square meters, including 50, 000 square meters of building area, and has more than 120 staff members and professional workers accounting for one third. Our fixed assets of 90, 000, 000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity.

Henan Hongda Cable Co. Ltd. Is the original Zhengzhou Hongda Cable Co. Ltd. Established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products, We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables' biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 70 (sets) domestic and oversea-leading production and testing equipment.

Our company's products have passed the ISO9001 Quality Management System Certification, the products also passed China Compulsory Certification (3C certification).

Our company insists on the principle of "Taking high and new technology as guide and being based on modern management". Our products sell well all over the world and the main reason is that we attach great importance to business honesty. We sincerely hope to be your partner.

Send your message to this manufacturer

More >

Other Products with This Manufacturers