| Prod Model: |
CX-WR |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Temperature Range: |
-200-800c |
| Fixing: |
Thread/Flange/None |
| Connection: |
Terminal Box/Compensation Cable/Plug |
| Probe Length: |
Custom |
| Thermocouple Wire Element: |
Simplex/Duplex |
| Graduation: |
N,K,E,T,J,PT100,Cu50,Cu100 |
| Pakage: |
Wooden Box |
| Thermalwell Material: |
Ss304,316,Inconel601 |
| Accuracy: |
5% |
Product Description
Special Thermocouple for Splitting Furnace(CX-WR)
Brief introduction:
It is usually connected with display meter, recording meter and computer ect.
To directly measure the temperature of liquid, vaper, gas and solid surface
ranging from -200 to 800C during various production processes.
How to choose?
1.Diameter and length:Can be customized as customer's requirements
2.Junction box: water-proof type, splash-proof type, anti-explosion type, connector type,import type.
3.Fixed device: flange/none/screw.
4.Temperature Range: -200-800C centigrade .
5.Terminal blocks: terminals box
Application
It is used for temperature test & control during production process under high temperature and pressure such as petroleum and chemical industry, and is the necessary temperature-measuring device in refinery and HVPE production.
Main Technical Parameters
Electric Outlet: M20×1.5 NPT1/2
Connection Size: M20×1.5 NPT1/2
Protection Class: IP65
Explosion-separation Class: dIIBT4, dIICT5
Nominal Pressure: 15~40MPa
Type & Specification
| Type | Graduation | Measuring Range °C | Thermal Response Time | Protection Tube Material | L×1 |
| WRNG-430 | N | 0~1000 | <180S | 1Cr18Ni9Ti | 380×150 430×200 480×250 530×300 580×350 630×400 680×450 |
| WRN2G-430 |
| WREG-430 | E | 0~800 |
| WRE2G-430 |
| WRNG-440 | K | 0~1000 |
| WRN2G-440 |
| WREG-440 | E | 0~800 |
| WRE2G-440 |
We provide different class I thermocouple as user's demand.
We also produce protection tube of other material.
Type 430 is water-proof one, and type 440 is explosion-separation one.
Protection Tube Material & Selection
| Material | Operation Temperature ºC | Characters & Application |
| 1Cr18Ni9Ti | -200~800 | Corrosion resistance under high temperature, usually used as general heat-resistant steel |
| 304 | -200~800 | Low carbon content, strong corrosion resistance, usually used as general heat-resistant steel |
| 316 | -200~750 | Low carbon content, strong corrosion resistance, used as corrosion-resistant steel |
| 316L | -200~750 | Extra low carbon content, strong corrosion resistance, used as corrosion-resistant steel |
| 310S | -200~1000 | Oxidization & corrosion resistance under high temperature, usually used as heat-resistant steel |
| GH3030 | 0~1100 | Nickel-base alloy steel resisting high temperature, oxidization & corrosion, usually used as heat-resistant steel |
Protection Tube Selection
Flange Selection: 900( PN15)~2500LB(PN40) RJ.
| Code | N | M | D | d | D1 | D2 |
| A | M20×1.5 NPT1/2 | NPT1" | Φ34 | Φ9 | Φ23 | Φ18 |
| B | NPT11/4" | Φ45 | Φ9 | Φ28 | Φ23 |
Flange Type & Specification
Flange Standard Code
| Standard Code | Document NO. |
| China National Standard | GB9112~9131-88 |
| Ministry of Chemical Industry Standard (China) | HG20592~20635~97 HGJ44~76~91 (HG5001~5028-58) |
| Ministry of Machinery Standard (China) | JB/T74~90-94 (JB81~82-59) |
| U.S. Standard | ASME/ANSI B16.5-88 |
| Germen Standard | DIN 2628~2638-1975 |
| Japan Standard | JIS2201-1796 |
Flange Specification
CLASS150~600 RF
CLASS900~2500 RJ
Notices in Type Selection
ype
Graduation
Accuracy
Protection Tube Material & Form
Flange Specification & Form
Length or Insert Length
Example A : Explosion-separation thermocouple under high temperature & pressure, type K, class I, protection tube class A, 300mm for insert length
WRNG-440A L×I+450×300 dIIBT4 316L
ANSI 1" 1500#RJ
After-sales service:
We promise to deliver the following after-sales service:
1. Warranty: The warranty period is 12 months starting from the shipping date;
2. Customers will enjoy free repair services for failures found within the warranty due to manufacturing quality;
3. For on-site services not arising from manufacturing quality, we shall charge a certain service fee at our discretion based on actual charges incurred such as travel expense;
4. We provide paid repair services for meter damages not arising from manufacturing quality issues or meter damages not within the scope of warranty.
Payment Terms:
1.Loading Port: Shanghai China
2. Samples Leading Time: 3-7 working days
3. Delivery Time: Within 7-15 days after payment
4.Payment: T/T, Western Union, Paypal
Our Integrity Promises your Quality !
Please contact with me, I will provide you professional service and high quality products.
Cixi flowmeter Co., Ltd. Was established in 2008 and since then has been dedicating itself to research and manufacture of various kinds of flowmeter. With sophisticated experience in technology and management, CIXI Flowmeter has made a name for itself as an excellent manufacturer of various kinds of flowmeter. In 2007, we have especially set up Shanghai Cixi Instrument Co. Ltd for handling the deals of Export.
Thanks to outstanding performance of products, CIXI Flowmeters are being applied in more and more fields where there' S liquid to measure. CIXI Flowmeters have found users in many countries besides China, such as Malaysia, India, Thailand, Vietnam, South Africa and so on. Increasing number of users are finding that CIXI Flowmeter are kind of product with super performance and reasonable price.