36kv Indoor Single-Phase Voltage Transformer with Embeded Fuse

JDZX10-36R voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 36 kV.High voltage outgoing line of prima

Shenzhen Chuangyin Co., Ltd.

36kv Indoor Single-Phase Voltage Transformer with Inbuilt Fuse

JDZX10-36R voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 36 kV.High voltage outgoing line of prima

Shenzhen Chuangyin Co., Ltd.

Voltage Transformer and Current Transformer 17.5kv Outdoor Three-Phase Epoxy Resin Type Current Sensor

JLSZXW5-17.5F VOLTAGE TRANSFORMER17.5kV Outdoor Single-Phase Epoxy Resin TypeTechnical Data1. Installation site Outdoor2. Rated Frequency 50/60Hz3. Burden power factor CosΦ=0.8(lagging)4. Technical standard accords with IEC 61869-1:2007,IEC 61869-2:2012, IEC 61869-3:2011Specification(Voltage tra

Shenzhen Chuangyin Co., Ltd.

Jlszxw3-17.5f Outdoor Combined Transformer

JLSZXW3-17.5F Outdoor Combined TransformerOutline DrawingMain technical parameterRated frequency: 50/60Hz: Rated insulation level: 17.5/38/95kVTypeRated Voltage ratio(V)Accuracy classRated output (VA)Rated current ratio(A)Accuracy classRated output (VA)JLSZXW3-17.5F12470/√3/12012470/√3/1

Shenzhen Chuangyin Co., Ltd.

Jlszxw1-36 Outdoor Combined Transformer Three-Phase

JLSZXW1-36 Outdoor Combined Transformeroutline DrawingMain technical parameterRated frequency: 50/60Hz:Rated insulation level: 36/70/170kV (IEC) or 40.55/95/200kV (GB)TypeRated Voltage ratio(V)Accuracy classRated output (VA)Rated current ratioAccuracy classRated output (VA)JLSZXW1-3635400/√3/1

Shenzhen Chuangyin Co., Ltd.

Jlszx8-12W Three-Phase Outdoor Cycloaliphatic Epoxy Resin Casting Combined Transformer

JLSZX8-12W, JLSZX8-17.5W HT METERING UNIT SETDescriptionJLSZX8-12W three-phase outdoor cycloaliphatic epoxy resin casting combined transformer (also called HT Metering Unit ), is made up of made up of three single phase semi insulating PTs(Y0-Y0 connection ) and three CTs ( cascade at A, B and C) ;

Shenzhen Chuangyin Co., Ltd.

12kv Outdoor Single-Phase Epoxy Resin Type Voltage Transformer for Mv Switchgear

JDZXW18-12 VOLTAGE TRANSFORMER12kV Outdoor Single-Phase Epoxy Resin TypeTechnical Data1. Installation site Outdoor2. Rated Frequency 50/60Hz3. Burden power factor CosΦ=0.8(lagging)4. Technical standard accords with IEC 61869-1:2007, IEC 61869-3:2011SpecificationTypeRated primary Voltage(KV)Rated

Shenzhen Chuangyin Co., Ltd.

24kv Indoor Single-Phase Epoxy Resin Type PT with Embeded Fuse

JDZX12-24R VOLTAGE TRANSFORMER24kV Indoor Single-Phase Epoxy Resin TypeTechnical Data1. Installation site Indoor2. Rated Frequency 50/60Hz3. Burden power factor CosΦ=0.8(lagging)4. Technical standard accords with IEC 61869-1:2007, IEC 61869-3:2011SpecificationTypeRated primary Voltage(KV)Rated s

Shenzhen Chuangyin Co., Ltd.

12kv Outdoor Single-Phase Epoxy Resin Type Voltage Transformer

JDZW18-12R VOLTAGE TRANSFORMER12kV Outdoor Single-Phase Epoxy Resin Type Technical Data1. Installation site Outdoor2. Rated Frequency) 50/60Hz3. Burden power factor CosΦ=0.8(lagging)4. Technical standard accords with IEC 61869-1:2007, IEC 61869-3:2011SpecificationTypeRated primary Voltage(kV)Rat

Shenzhen Chuangyin Co., Ltd.

Voltage Transformer 12kv Outdoor Single-Phase Epoxy Resin Type Power Transformer

JDZW2-12RF VOLTAGE TRANSFORMER12kV Outdoor Single-Phase Epoxy Resin TypeTechnical Data1. Installation site Outdoor2. Rated Frequency 50/60Hz3. Burden power factor CosΦ=0.8(lagging)4. Technical standard accords with IEC 61869-1:2007, IEC 61869-3:2011SpecificationTypeRated primary Voltage(KV)Rated

Shenzhen Chuangyin Co., Ltd.

17.5kv Outdoor Combined Transformer Single-Phase Epoxy Resin Type

LZZW3-12 CURRENT TRANSFORMER12kV Outdoor Single-Phase Epoxy Resin TypeTechnical Data1. Rated insulation level: 12/42/75 kV(GB)or 17.5/38/95 (IEC)2. Rated frequency: 50/60Hz3. Installation site: Outdoor4. Technical standard: IEC 61869-1:2007, IEC 61869-3:2011

Shenzhen Chuangyin Co., Ltd.

Lzzbj6-12A\Lzzbj6-12b\Lzzbj6-12c Current Transformer 12kv Indoor Single-Phase Epoxy Resin Type

LZZBJ6-12A,LZZBJ6-12B,LZZBJ6-12C CURRENT TRANSFORMER12kV Indoor Single-Phase Epoxy Resin TypeTechnical Data1.Rated insulation level: 12/28/75 kV or 12/42/75 kV2. Rated frequency: 50/60Hz3. Installation site: Indoor4. Technical standard: IEC 61869-1:2007,IEC 61869-2:2012 GB 20840.1-2010,GB 20840.2-20

Shenzhen Chuangyin Co., Ltd.

12kv Outdoor Doublepole Potential Transformer or Vt for Mv Switchgear

JDZXW-17.5(24)voltage transformer, outdoor epoxy resin casting and full-enclosed construction, is widely used for measuring current, electric energy and protective relaying in the single-phase or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 17.5kV or 24k

Shenzhen Chuangyin Co., Ltd.

12kv Outdoor Doublepole Potential Transformer or Voltage Transformer

JDZXW-17.5(24)voltage transformer, outdoor epoxy resin casting and full-enclosed construction, is widely used for measuring current, electric energy and protective relaying in the single-phase or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 17.5kV or 24k

Shenzhen Chuangyin Co., Ltd.

36kv Indoor Single Pole Potentia Transformerl Voltage Transformer/PT/Vt with Fuse

JDZX10-36RG voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 36 kV.High voltage outgoing line of prim

Shenzhen Chuangyin Co., Ltd.

12kv Indoor Epoxy Resin Busbar Type CT /Current Transformer for Mv Switchgear (1000~5000/5, 0.2S~10P)

LMZB(J)2-11 epoxy resin casting busbar type current transformer, is widely used for measuring current, electric energy and protective relaying in the electrical system with rated frequency 50Hz or 60Hz and highest voltage for equipment 7.2/12kV. The product has three secondary windings (one measurin

Shenzhen Chuangyin Co., Ltd.

12kv Indoor Epoxy Resin Current Transformer for Mv Switchgear (400~1500; 0.2S~10P)

LDZB6-11 current transformers(CT) epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body.The product has the feature of lightweight, omni-directional installation withstanding nastiness and dampne

Shenzhen Chuangyin Co., Ltd.

12kv Indoor Current Transformer (5~1000/5; 0.2S~10P) for Mv Switchgear

LAJ1-11QIIcurrent transformers(CT) epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body.The product has large external insulation creepage distance, withstands nastiness and dampnessIt is widely

Shenzhen Chuangyin Co., Ltd.

11kv Indoor Small Size CT or Current Transformer for Mv Switchgear

LZZBJ6-11Q,LZZBJ6-11A,LZZBJ6-11B current transformer(CT), epoxy resin casting insulation and fully enclosed support construction, encloses the primary & secondary windings and annular core in the epoxy resin casting body.The product has two secondary winding (one measuring widely and one protective

Shenzhen Chuangyin Co., Ltd.

Distribution Transformer; Buried Type Distribution Transformer

S11-MD Series Buried type Distribution transformer General: Buried type distribution transformer is a kind of new environment friendly transformer, researched and developed according to the trend that urban and rural power supply distribution transformer tends to bury below the ground and also due

Ningbo Ville Electric Co., Ltd.