| Prod Model: |
GS Series 1~12KW |
| Dimention: |
480*336*190mm |
| Weight: |
20-50kg |
| Display: |
LED,LCD for PV,Inverter and Battery |
| Output Waveform: |
Pure Sine Wave |
| Solar Charger: |
MPPT Solar Charger Controller 40/60AMP |
| Set: |
DC or AC Priority |
| Application: |
Solar Power System Home |
| Peak Power: |
3 Tines as Rated Power |
| Protection: |
Overload,Output Short-Circuit Protection |
| Efficiency: |
98% |
Product Description
1000W - 12000W 12V/24V/48V AC Single Phase Off Grid Hybrid Solar Power Panel InverterWith reliable intelligent design,GS series solar inverter can be avaiilable to complicated appliance. Not only used for common appliances such as TV,computwe,lights,fans...but also suitable for inductive loading such as refrigerators,airconditioners,motors,pumps,compressors and laser printers.♦ GS Series AC/Solar charging Off grid Hybrid Inverter.
♦ LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design.
♦ Built-in 40A/60A optional MPPT solar charger controller.
♦ LCD shows the solar capacity.
♦ 5 stages adjustable AC charging current. AC charging also can be closed.
♦ AC/DC priority modes can be set.
♦ Generator restart signal. (Dry contact)
♦ 3 times peak power. Strong loading capacity.
♦ Overload, output short-circuit protection.
| Model Parameters | GS1000W | GS2000W | GS2500W | GS3000W |
AC Input | Nominal Power | 1000W | 2000W | 2500W | 3000W |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal input Voltage | 120/230VAC |
| Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V |
| High Line Disconnect | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V |
| Max AC input Voltage | 120V for Max150V, 230V for Max270V |
| Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz |
AC output | Output Voltage Waveform | Sine wave |
| Power Factor | 0.9~1.0 |
| Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms |
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz, 50Hz ± 0.3Hz |
Solar charger | Rated Charge Current | 40A | 60A |
| PV Input Voltage range | 15VDC-40VDC for 12VDC, 30VDC-55VDC for 24VDC, 60-110VDC for 48V |
Max.PV open circuit array voltage | 12V for 40Vdc, 24V for 55Vdc, 48V for 110Vdc |
| Charger mode | MPPT |
PV Low Voltage Re-connect | PV≥Bat.V+3V |
PV Low Voltage Disconnect | PV<=Bat.V |
| Efficiency | ≥97% |
AC Charger | Nominal Charger Current | 35A/50A/70A/90A(According to the inverter model) |
| 5 stages adjustable charging current |
| Over charge Protection | Bat.V≥15.5VDC for 12V battery, Bat.V≥31.0VDC for 24V battery ,Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
| Efficiency | Efficiency(Battery Mode) | ≥87% |
| Efficiency (Line Mode) | >98% |
Battery Voltage | Nominal DC input Voltage | 12/24/48VDC |
| Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC |
| 21VDC±0.6VDC for 24VDC |
| 42VDC±1.2VDC for 48VDC |
High DC input Alarm & Fault | 16VDC±0.3VDC for 12VDC |
| 32VDC±0.6VDC for 24VDC |
| 64VDC±1.2VDC for 48VDC |
| | Transfer Time | 20ms(max) |
System Parameter | Over-Load Protection | 110%<load<150%, beeps 0.5s every 1s, and Fault after 60s off the output,load>150%, beeps 0.5s every 1s, and Fault after 20s |
Output Short Circuit Protection | Current limit (Fault after 10s) |
| Surge Rating(10s) | 1:3(VA) |
| Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) |
| Protections | Low battery, over charging, over load, over temp |
General Specifications | Operating Temperature Range | 0ºC~40ºC |
| Storage Temperature | -15ºC~60ºC |
| Operation humidity | 5% to 95%(non-condensing) |
| Audible Noise | 60dB max |
| cooling | Forced air,variable speed fan |
| Dimension(L*W*H) | 480*336*190mm |
| Net Weight(kg) | 19.5 | 23.5 | 25.5 | 28 |
| Parameters Model | GS4000W | GS5000W | GS6000W | GS7000W | GS8000W | GS10KW |
AC Input | Nominal Power | 4000W | 5000W | 6000W | 7000W | 8000W | 10KW |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal input Voltage | 120/230VAC | 230VAC |
| Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V / 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V |
| Low Line Re-connect | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V / 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V |
| High Line Disconnect | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V / 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V |
| High Line Re-connect | 131Vac±4%(Normal) or 135Vac±4% (Wide) for 120V / 253Vac±4%(Normal) or 253Vac±4%(Wide) for 230V |
| Max AC input Voltage | 120V for Max150V | 230V for Max270V |
| Frequency | 50Hz:41-54Hz / 60Hz:51-64Hz |
AC output | Output Voltage Waveform | Sine wave |
| Power Factor | 0.9~1.0 |
| Nominal Output Voltage (V) | LV:120Vac ±10%rms / HV:230Vac ±10%rms | HV:230Vac ±10%rms |
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz |
Solar charger | Rated Charge Current | 60A |
| PV Input Voltage range | 30VDC-55VDC for 24VDC / 60-110VDC for 48V |
Max.PV open circuit array voltage | 24V for 55Vdc / 48V for 110Vdc |
| Charger mode | MPPT |
PV Low Voltage Re-connect | PV≥Bat.V+3V |
PV Low Voltage Disconnect | PV<=Bat.V |
| Efficiency | ≥97% |
AC Charger | Nominal Charger Current | 35A/50A/70A(According to the inverter model) |
| 5 stages adjustable charging current |
| Over charge Protection | Bat.V≥31.0VDC for 24V battery ,Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s |
| Three-stage charging | Three stage:Boost cc (constant current stage) |
| Boost CV (constant voltage stage) |
| float (conatant voltage stage) |
| Efficiency | Efficiency(Battery Mode) | ≥87% |
| Efficiency (Line Mode) | >98% |
Battery Voltage | Nominal DC input Voltage | 24/48VDC | 48VDC |
| Low Battery Alarm | 21VDC±0.6VDC for 24VDC |
| 42VDC±1.2VDC for 48VDC |
| Low DC input shut-down | 20VDC±0.6VDC for 24VDC |
| 40VDC±1.2VDC for 48VDC |
High DC input Alarm & Fault | 32VDC±0.6VDC for 24VDC |
| 64VDC±1.2VDC for 48VDC |
High DC input Recovery | 31VDC±0.6VDC for 24VDC |
| 62VDC±1.2VDC for 48VDC |
Transfer Time | AC to DC | 20ms(max) |
| DC to AC | 15ms(max) |
System Parameter | Over-Load Protection | 110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off the output,load>150%,beeps 0.5s every 1s,and Fault after 20s |
Output Short Circuit Protection | Current limit (Fault after 10s) |
| Surge Rating(10s) | 1:3(VA) |
| Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) |
| Protections | Low battery, over charging, over load, over temp |
| Indicators | LED+LCD Display |
General Specifications | Operating Temperature Range | 0ºC to 40ºC |
| Storage Temperature | 15ºC~60ºC |
| Operation humidity | 5% to 95%(non-condensing) |
| Audible Noise | 60dB max |
| cooling | Forced air,variable speed fan |
| Dimension(L*W*H) | 530*400*190mm | 627*416*204mm |
| Net Weight(kg) | 30.0kg | 35.5kg | 38.5kg | 41.5kg | 48.0kg | 55.0kg |

Our Company:Shenzhen ZLPOWER Electronics Co., Ltd established on 2006 years. We are national high-tech enterprise which professional researching, manufacturing and exporting UPS power supply, Inverter power supply, Solar inverter, Car charging pile, EPS power supply. Our power products capacity from 400VA to 400KVA parallel series parallel series, which can satisfy different fields customers requirements.
ZLPOWER Company had passed ISO 9001, ISO 14001 and our products had passed Thayer certification, CE certification, UL certification, ETL certification, CCC certification......Our product are sold all over the world, mainly exported countries and areas include Europe, Africa, Middle East, Asia, USA, Canada...Our products widely used for military, finance, communication, medical treatment, industry, public security and civil power solutions.


Why choose us:1.More than 11 years experience in the field of UPS power supply and Solar power system.
2.Our experienced R&D team enables us to build customized product lines for clients.
3.Free OEM Service, Fast Lead Time 7-30 days, High Quality (CE&ISO)
4. Good quality and competitive price.
FAQ:Q1. How to choose the right Inverter?
1. Understand specifications of all inverter.
2. Consider the requirements of power quality.
3. Understand the current capacity of inverter and consider the future expanding.
4. Choose inverter based on your concrete requirements.
Q2. What are important factors you should consider when buying inverter?
1. inverter's reliability and stability.
2. The excellent engineers and the ability of products creation.
3. High efficiency and low noise.
4. Supplier's reputation and financial situation.
5. International safety certificate such as UL, CCC, etc.
6. Plant certifications such as ISO9001, ISO14001, etc. Q3.How about our service?
As a user of ZLPOWER, you have the following service:
1. Two years warranty (covering batteries purchased from ZLPOWER)
2. 24-hour helpline; Service helpline: 0086-755-29105850
3. Nationwide warranty
4. Technical support on our website: www.zlpower.com