| Prod Model: |
YJV32 power cable |
| Standard: |
IEC 60502-1 |
| Rated Voltage: |
0.6/1 Kv |
| Use: |
Underground |
| Application: |
in Cable Ducts, Under Ground, in Power and Switchi |
| Voltage: |
Low and Medium Voltage Cable |
| Current: |
DC Cable |
| Insulation Material: |
XLPE |
| Certification: |
SGS |
| Model: |
Yjv32 |
| Brand: |
Hongda |
Product Description
0.6/1kV YJV32 Copper Conductor Steel Armored 3x150+1x70 Power CableCU/XLPE/LSZH/SWA/LSZH (2 Cores - 5 Cores)
XLPE Insulated, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable
Power Cable Application:
These power cable for fixed installations such as distribution networks or industrial installations.
Such as Plant engineering; Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc.
Armoured cable suitable for direct burial.
Power Cable Construction:
Conductor: Plain annealed copper, class1 solid or class 2 stranded as per IEC 60228.
Flexible class 5 or tinned conductor could be offer upon request.
Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1.
Insulation Colour:
| Number of Cores | Color Code to IEC 60502-1 | Color Code to BS 5467 |
2 | Red & Black | Brown & Blue |
| 3 | Red, Yellow and Blue | Brown, Black and Grey |
| 4 | Red, Yellow, Blue and Black | Blue, Brown, Black and Grey |
| 5 | Red, Yellow, Blue, Black and Green / Yellow | Green / Yellow, Blue, Brown, Black and Grey |
Assembly: Cores cabled together with PP filler and covered with non-woven tape.
Bedding: Low smoke zero halogen (LSZH) compound ST8 (90°C) of IEC 60502-1.
Bedding Colour: Black or other color as per customer request.
Armour: Galvanized steel wire armoured (SWA).
Outer Sheath: Low smoke zero halogen (LSZH) compound ST8 (90°C) of IEC 60502-1.
Outer Sheath Colour: Black or other color as per customer request.
Power Cable Electrical CharacteristicsRecommended rated voltages U0
Highest system voltage (U m ) (kV) | Rated voltage (U 0 ) (kV) |
| Categories A and B | Category C |
| 1.2 | 0.6 | 0.6 |
Routine test voltages
| Rated voltage U 0 (kV) | 0.6 |
| Test voltage (kV) | 3.5 |
Maximum conductor temperatures for different types of insulating compound
| Maximum conductor temperature (°C) |
| Normal operation | Short-circuit (5 s maximum duration) |
| 90 | 250 |
Operating Temperature: -15°C to 90°C
Test Voltage: 3.5 kV for 5 minutes
Reference Standards
Design Specification: BS6724
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2
Installation Reference
Min.Bending Radius (mm): 8 x cable overall diameter
Max.Pulling Tension (N/mm 2 ): 70
Low Voltage Power Cable (0.6/1 kV)
XLPE insulated, copper conductor, Steel Wire Armour, LSZH cableDimension
2 Cores
| Nominal Conductor Area(mm2) | No.and Diameter of Wires (no./mm) | Thickness of Insulation (mm) | Diameter Under Armour (mm) | Thickness of Bending (mm) | Diameter of Armour Wire (mm) | Thickness of Sheath (mm) | Overall Diameter (mm) | Approximate Weight (kg/km) |
| 2X1.5 | 7/0.53 | 0.7 | 8 | 1 | 0.8 | 1.8 | 13.2 | 325 |
| 2X2.5 | 7/0.67 | 0.7 | 8.8 | 1 | 0.8 | 1.8 | 14 | 372 |
| 2X4 | 7/0.85 | 0.7 | 9.9 | 1 | 0.8 | 1.8 | 15.1 | 438 |
| 2X6 | 7/1.04 | 0.7 | 11 | 1 | 1.25 | 1.8 | 17.1 | 645 |
| 2X10 | 7/1.35 | 0.7 | 12.9 | 1 | 1.25 | 1.8 | 19 | 806 |
| 2X16 | 7/1.70 | 0.7 | 15 | 1 | 1.25 | 1.8 | 21.1 | 1015 |
| 2X25 | 7/2.14 | 0.9 | 18.4 | 1 | 1.6 | 1.8 | 25.2 | 1517 |
| 2X35 | 7/2.52 | 0.9 | 20.7 | 1 | 1.6 | 1.8 | 27.5 | 1830 |
| 2X50 | 19/1.78 | 1 | 23.8 | 1 | 1.6 | 1.9 | 30.8 | 2259 |
| 2X70 | 19/2.14 | 1.1 | 28.2 | 1.2 | 2 | 2.1 | 36.4 | 3249 |
| 2X95 | 19/2.52 | 1.1 | 32 | 1.2 | 2 | 2.2 | 40.4 | 4043 |
| 2X120 | 37/2.03 | 1.2 | 35.6 | 1.2 | 2.5 | 2.4 | 45.4 | 5254 |
| 2X150 | 37/2.25 | 1.4 | 39.9 | 1.4 | 2.5 | 2.5 | 49.9 | 6211 |
| 2X185 | 37/2.52 | 1.6 | 44.5 | 1.4 | 2.5 | 2.7 | 54.9 | 7403 |
| 2X240 | 61/2.25 | 1.7 | 50.5 | 1.6 | 2.5 | 2.9 | 61.3 | 9175 |
| 2X300 | 61/2.52 | 1.8 | 55.8 | 1.6 | 2.5 | 3.1 | 67 | 10939 |
| 2x400 | 61/2.85 | 2 | 62.5 | 1.6 | 3.15 | 3.4 | 75.6 | 14295 |
| 2x500 | 61/3.20 | 2.2 | 70 | 1.8 | 3.15 | 3.6 | 83.5 | 17282 |
| 2x630 | 127/2.52 | 2.4 | 78.7 | 1.8 | 3.15 | 3.9 | 92.8 | 21253 |
| 2x800 | 127/2.85 | 2.6 | 88.5 | 2 | 3.15 | 4.3 | 103.4 | 26200 |
| 2x1000 | 127/3.20 | 2.8 | 98.4 | 2 | 3.15 | 4.6 | 113.9 | 31788 |
3 Cores
Nominal Conductor Area (mm2) | No.and Diameter of Wires (no./mm) | Thickness of Insulation (mm) | Diameter Under Armour (mm) | Thickness of Bending (mm) | Diameter of Armour Wire (mm) | Thickness of Sheath (mm) | Overall Diameter (mm) | Approximate Weight (kg/km) |
| 3X1.5 | 7/0.53 | 0.7 | 8.4 | 1 | 0.8 | 1.8 | 13.6 | 361 |
| 3X2.5 | 7/0.67 | 0.7 | 9.3 | 1 | 0.8 | 1.8 | 14.5 | 420 |
| 3X4 | 7/0.85 | 0.7 | 10.5 | 1 | 1.25 | 1.8 | 16.6 | 629 |
| 3X6 | 7/1.04 | 0.7 | 11.7 | 1 | 1.25 | 1.8 | 17.8 | 742 |
| 3X10 | 7/1.35 | 0.7 | 13.7 | 1 | 1.25 | 1.8 | 19.8 | 954 |
| 3X16 | 7/1.70 | 0.7 | 16 | 1 | 1.6 | 1.8 | 22.8 | 1372 |
| 3X25 | 7/2.14 | 0.9 | 19.7 | 1 | 1.6 | 1.8 | 26.5 | 1857 |
| 3X35 | 7/2.52 | 0.9 | 22.2 | 1 | 1.6 | 1.8 | 29 | 2281 |
| 3X50 | 19/1.78 | 1 | 25.5 | 1 | 2 | 2 | 33.5 | 3118 |
| 3X70 | 19/2.14 | 1.1 | 30.2 | 1.2 | 2 | 2.1 | 38.4 | 4107 |
| 3X95 | 19/2.52 | 1.1 | 34.3 | 1.2 | 2 | 2.3 | 42.9 | 5217 |
| 3X120 | 37/2.03 | 1.2 | 38.6 | 1.4 | 2.5 | 2.5 | 48.6 | 6808 |
| 3X150 | 37/2.25 | 1.4 | 42.8 | 1.4 | 2.5 | 2.6 | 53 | 8027 |
| 3X185 | 37/2.52 | 1.6 | 47.7 | 1.4 | 2.5 | 2.8 | 58.3 | 9655 |
| 3X240 | 61/2.25 | 1.7 | 54.1 | 1.6 | 2.5 | 3 | 65.1 | 12085 |
| 3X300 | 61/2.52 | 1.8 | 59.8 | 1.6 | 2.5 | 3.2 | 71.2 | 14540 |
| 3X400 | 61/2.85 | 2 | 67.5 | 1.8 | 3.15 | 3.5 | 80.8 | 19015 |
| 3x500 | 61/3.20 | 2.2 | 75.1 | 1.8 | 3.15 | 3.8 | 89 | 23090 |
| 3x630 | 127/2.52 | 2.4 | 84.9 | 2 | 3.15 | 4.1 | 99.4 | 28777 |
| 3x800 | 127/2.85 | 2.6 | 95 | 2 | 3.15 | 4.5 | 110.3 | 35573 |
| 3x1000 | 3x1000 | 2.8 | 105.7 | 2 | 3.15 | 4.9 | 121.8 | 43549 |
4 Cores
Nominal Conductor Area (mm2) | No.and Diameter of Wires (no./mm) | Thickness of Insulation (mm) | Diameter Under Armour (mm) | Thickness of Bending (mm) | Diameter of Armour Wire (mm) | Thickness of Sheath (mm) | Overall Diameter (mm) | Approximate Weight (kg/km) |
| 4X1.5 | 7/0.53 | 0.7 | 9.2 | 1 | 0.8 | 1.8 | 14.4 | 406 |
| 4X2.5 | 7/0.67 | 0.7 | 10.2 | 1 | 1.25 | 1.8 | 16.3 | 600 |
| 4X4 | 7/0.85 | 0.7 | 11.5 | 1 | 1.25 | 1.8 | 17.6 | 718 |
| 4X6 | 7/1.04 | 0.7 | 12.9 | 1 | 1.25 | 1.8 | 19 | 859 |
| 4X10 | 7/1.35 | 0.7 | 15.2 | 1 | 1.6 | 1.8 | 22 | 1259 |
| 4X16 | 7/1.70 | 0.7 | 17.7 | 1 | 1.6 | 1.8 | 24.5 | 1628 |
| 4X25 | 7/2.14 | 0.9 | 21.8 | 1 | 1.6 | 1.8 | 28.6 | 2237 |
| 4X35 | 7/2.52 | 0.9 | 24.6 | 1 | 1.6 | 1.9 | 31.6 | 2794 |
| 4X50 | 19/1.78 | 1 | 28.7 | 1.2 | 2 | 2.1 | 36.9 | 3862 |
| 4X70 | 19/2.14 | 1.1 | 33.5 | 1.2 | 2 | 2.3 | 42.1 | 5086 |
| 4X95 | 19/2.52 | 1.1 | 38.5 | 1.4 | 2.5 | 2.5 | 48.5 | 7023 |
| 4X120 | 37/2.03 | 1.2 | 42.9 | 1.4 | 2.5 | 2.6 | 53.1 | 8428 |
| 4X150 | 37/2.25 | 1.4 | 47.6 | 1.4 | 2.5 | 2.8 | 58.2 | 10016 |
| 4X185 | 37/2.52 | 1.6 | 53.5 | 1.6 | 2.5 | 3 | 64.5 | 12185 |
| 4X240 | 61/2.25 | 1.7 | 60.3 | 1.6 | 3.15 | 3.3 | 73.2 | 16156 |
| 4X300 | 61/2.52 | 1.8 | 67 | 1.8 | 3.15 | 3.5 | 80.3 | 19518 |
| 4X400 | 61/2.85 | 2 | 75.2 | 1.8 | 3.15 | 3.8 | 89.1 | 24020 |
| 4x500 | 61/3.20 | 2.2 | 84.1 | 2 | 3.15 | 4.1 | 98.6 | 29408 |
| 4x630 | 127/2.52 | 2.4 | 94.7 | 2 | 3.15 | 4.5 | 110 | 36693 |
| 4x800 | 127/2.85 | 2.6 | 106 | 2 | 3.15 | 4.9 | 122.1 | 45523 |
| 4x1000 | 127/3.20 | 2.8 | 117.9 | 2 | 3.15 | 5.3 | 134.8 | 55907 |
5 Cores
Nominal Conductor Area (mm2) | No.and Diameter of Wires (no./mm) | Thickness of Insulation (mm) | Diameter Under Armour (mm) | Thickness of Bending (mm) | Diameter of Armour Wire (mm) | Thickness of Sheath (mm) | Overall Diameter (mm) | Approximate Weight (kg/km) |
| 5x1.5 | 7/0.53 | 0.7 | 10.1 | 1 | 1.25 | 1.8 | 16.2 | 573 |
| 5X2.5 | 7/0.67 | 0.7 | 11.2 | 1 | 1.25 | 1.8 | 17.3 | 671 |
| 5X4 | 7/0.85 | 0.7 | 12.7 | 1 | 1.25 | 1.8 | 18.8 | 812 |
| 5X6 | 7/1.04 | 0.7 | 14.2 | 1 | 1.25 | 1.8 | 20.3 | 981 |
| 5X10 | 7/1.35 | 0.7 | 16.7 | 1 | 1.6 | 1.8 | 23.5 | 1446 |
| 5X16 | 7/1.70 | 0.7 | 19.6 | 1 | 1.6 | 1.8 | 26.4 | 1892 |
| 5X25 | 7/2.14 | 0.9 | 24.2 | 1 | 1.6 | 1.9 | 31.2 | 2644 |
| 5x35 | 7/2.52 | 0.9 | 27.7 | 1.2 | 2 | 2.1 | 35.9 | 3648 |
| 5x50 | 19/1.78 | 1 | 31.8 | 1.2 | 2 | 2.2 | 40.2 | 4580 |
| 5x70 | 19/2.14 | 1.1 | 37.2 | 1.2 | 2.5 | 2.4 | 47 | 6507 |
| 5X95 | 19/2.52 | 1.1 | 42.8 | 1.4 | 2.5 | 2.6 | 53 | 8370 |
| 5X120 | 37/2.03 | 1.2 | 47.6 | 1.4 | 2.5 | 2.8 | 58.2 | 10113 |
| 5X150 | 37/2.25 | 1.4 | 53.3 | 1.6 | 2.5 | 3 | 64.3 | 12131 |
| 5X185 | 37/2.52 | 1.6 | 59.5 | 1.6 | 2.5 | 3.2 | 70.9 | 14693 |
| 5X240 | 61/2.25 | 1.7 | 67.5 | 1.8 | 3.15 | 3.5 | 80.8 | 19549 |
| 5X300 | 61/2.52 | 1.8 | 74.6 | 1.8 | 3.15 | 3.8 | 88.5 | 23599 |
| 5X400 | 61/2.85 | 2 | 84.1 | 2 | 3.15 | 4.1 | 98.6 | 29242 |
| 5x500 | 61/3.20 | 2.2 | 93.6 | 2 | 3.15 | 4.4 | 108.7 | 35726 |
| 5x630 | 127/2.52 | 2.4 | 105.4 | 2 | 3.15 | 4.9 | 121.5 | 44748 |
| 5x800 | 127/2.85 | 2.6 | 118.1 | 2 | 3.15 | 5.3 | 135 | 55631 |
| 5x1000 | 127/3.20 | 2.8 | 131.4 | 2 | 3.15 | 5.8 | 149.3 | 68518 |
Supplying you with customized iec60502 0.6 / 1 kv 2 cores -5 cores xlpe insulation lszh sheath steel wire armoured power cable, it is one of the reliable iec60502 0.6 / 1 kv 2 cores -5 cores xlpe insulation Lszh sheath steel wire armoured power cable manufacturers and suppliers, welcome to wholesale our products at good price from our factory.
Hot Tags: Armored Power Cable, Xlpe Armoured Cable Specifications, Armoured Cable, Armored Electric Cable, Steel Wire Armoured Xlpe Cable, 0.6/1 Kv Power Cable, 2 Cores To 5 Cores Power Cable, 0.6 /1 Kv Power Cable, Cu Xlpe Pvc Cable
Packing & Shipping:
Why Choose Us ?1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas.

FAQQ: Are you trading company or manufacturer ?A: We are factory.
Q: How long is your delivery time?A: Generally it is 5-10 days if the goods are in stock. or it is 10-20 days if the goods are not in stock,
it is according to quantity.
Q: Do you provide samples ? is it free or extra ?A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?A: 30% T/T in advance,70% T/T balance before shipment
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Any needs or question, please contact me Mobile:+86-15838290725 , we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperation.
Henan Hongda Cable Co., Ltd. Located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Our company covers an area of 100, 000 square meters, including 50, 000 square meters of building area, and has more than 120 staff members and professional workers accounting for one third. Our fixed assets of 90, 000, 000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity.
Henan Hongda Cable Co. Ltd. Is the original Zhengzhou Hongda Cable Co. Ltd. Established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products, We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables' biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 70 (sets) domestic and oversea-leading production and testing equipment.
Our company's products have passed the ISO9001 Quality Management System Certification, the products also passed China Compulsory Certification (3C certification).
Our company insists on the principle of "Taking high and new technology as guide and being based on modern management". Our products sell well all over the world and the main reason is that we attach great importance to business honesty. We sincerely hope to be your partner.