Henan Jiapu Cable Co., Ltd. >> High Performance Medium Voltage XLPE Insulated Unarmoured Power Cable

High Performance Medium Voltage XLPE Insulated Unarmoured Power Cable

High Performance Medium Voltage XLPE Insulated Unarmoured Power Cable
Price: Negotiable/Meter
Trade Terms: FOB,CFR,CIF
Min Order: 500/Meter
Pay Type: L/C,T/T,D/P,Western Union,Paypal
Prod Model: xlpe cable
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Voltage Rating: 0.6/1 Kv 3.6/6 Kv
No.of Cores: 1-5 Cores
Applicable Standard: IEC60502 IEC60331 DIN BS
Max Working Temp: 90 Degrees
Max Shott Circuit Temp: 250 Degrees
Application: Underground
Voltage: Low and Medium Voltage Cable
Current: DC Cable
Insulation Material: XLPE
Certification: SABS
Brand: Henan Jiapu

Product Description

High Performance Medium Voltage XLPE Insulated Unarmoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.


Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.12

1.5

17.6

0.34

0.49

1.2000

0.7270

35

7.0

2.5

0.12

1.5

18.5

0.39

0.60

0.8680

0.5240

50

8.3

2.5

0.12

1.6

20.0

0.46

0.74

0.6410

0.3870

70

9.7

2.5

0.12

1.6

21.5

0.55

0.96

0.4430

0.2680

95

11.3

2.5

0.12

1.7

23.3

0.66

1.23

0.3200

0.1930

120

13

2.5

0.12

1.7

24.8

0.77

1.48

0.2530

0.1530

150

14.6

2.5

0.12

1.8

26.4

0.87

1.77

0.2060

0.1240

185

15.9

2.5

0.12

1.8

28.1

1.01

2.13

0.1640

0.0991

240

18.3

2.6

0.12

1.9

30.9

1.23

2.71

0.1250

0.0754

300

20.4

2.8

0.12

2.0

33.6

1.48

3.32

0.1000

0.0601

400

23.2

3.0

0.12

2.1

37.0

1.81

4.16

0.0778

0.0470

500

26.4

3.2

0.12

2.2

41.1

2.24

5.27

0.0605

0.0366

630

30.1

3.2

0.12

2.3

45.0

2.73

6.62

0.0469

0.0283


2) 6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.12

1.5

19.4

0.40

0.55

1.2000

0.7270

35

6.9

3.4

0.12

1.6

20.5

0.45

0.66

0.8680

0.5240

50

8.2

3.4

0.12

1.6

21.8

0.52

0.80

0.6410

0.3870

70

9.7

3.4

0.12

1.7

23.5

0.62

1.03

0.4430

0.2680

95

11.3

3.4

0.12

1.7

25.1

0.73

1.30

0.3200

0.1930

120

12.8

3.4

0.12

1.8

26.8

0.85

1.56

0.2530

0.1530

150

14.2

3.4

0.12

1.8

28.2

0.95

1.85

0.2060

0.1240

185

15.9

3.4

0.12

1.9

30.1

1.10

2.22

0.1640

0.0991

240

18.3

3.4

0.12

2.0

32.7

1.33

2.80

0.1250

0.0754

300

20.4

3.4

0.12

2.0

34.8

1.54

3.39

0.1000

0.0601

400

23.2

3.4

0.12

2.2

38.0

1.87

4.22

0.0778

0.0470

500

26.4

3.4

0.12

2.2

41.5

2.26

5.29

0.0605

0.0366

630

30.1

3.4

0.12

2.4

45.6

2.78

6.67

0.0469

0.0283


3) 8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.12

1.6

21.8

0.48

0.63

1.2000

0.7270

35

6.9

4.5

0.12

1.7

22.9

0.54

0.75

0.8680

0.5240

50

8.2

4.5

0.12

1.7

24.2

0.61

0.89

0.6410

0.3870

70

9.7

4.5

0.12

1.8

25.9

0.72

1.13

0.4430

0.2680

95

11.3

4.5

0.12

1.8

27.5

0.84

1.40

0.3200

0.1930

120

12.8

4.5

0.12

1.9

29.2

0.96

1.67

0.2530

0.1530

150

14.2

4.5

0.12

1.9

30.6

1.06

1.96

0.2060

0.1240

185

15.9

4.5

0.12

2.0

32.5

1.22

2.34

0.1640

0.0991

240

18.3

4.5

0.12

2.1

35.1

1.46

2.93

0.1250

0.0754

300

20.4

4.5

0.12

2.1

37.2

1.68

3.52

0.1000

0.0601

400

23.2

4.5

0.12

2.2

40.2

2.00

4.35

0.0778

0.0470

500

26.4

4.5

0.12

2.3

43.9

2.43

5.45

0.0605

0.0366

630

30.1

4.5

0.12

2.4

47.8

2.93

6.83

0.0469

0.0283


4) 12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

6.9

5.5

0.12

1.7

24.9

0.62

0.83

0.8680

0.5240

50

8.2

5.5

0.12

1.8

26.4

0.70

0.98

0.6410

0.3870

70

9.7

5.5

0.12

1.8

27.9

0.80

1.21

0.4430

0.2680

95

11.3

5.5

0.12

1.9

29.7

0.94

1.50

0.3200

0.1930

120

12.8

5.5

0.12

1.9

31.2

1.05

1.77

0.2530

0.1530

150

14.2

5.5

0.12

2.0

32.8

1.17

2.07

0.2060

0.1240

185

15.9

5.5

0.12

2.0

34.5

1.33

2.45

0.1640

0.0991

240

18.3

5.5

0.12

2.1

37.1

1.57

3.04

0.1250

0.0754

300

20.4

5.5

0.12

2.2

39.4

1.81

3.66

0.1000

0.0601

400

23.2

5.5

0.12

2.3

42.4

2.14

4.49

0.0778

0.0470

500

26.4

5.5

0.12

2.4

46.1

2.58

5.61

0.0605

0.0366

630

30.1

5.5

0.12

2.4

49.8

3.10

6.99

0.0469

0.0283


5) 18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.12

2.0

31.8

0.95

1.23

0.6410

0.3870

70

9.7

8.0

0.12

2.0

33.3

1.07

1.47

0.4430

0.2680

95

11.3

8.0

0.12

2.1

35.1

1.21

1.78

0.3200

0.1930

120

12.8

8.0

0.12

2.1

36.6

1.34

2.05

0.2530

0.1530

150

14.2

8.0

0.12

2.2

38.2

1.47

2.37

0.2060

0.1240

185

15.9

8.0

0.12

2.2

39.9

1.64

2.76

0.1640

0.0991

240

18.3

8.0

0.12

2.3

42.5

1.90

3.37

0.1250

0.0754

300

20.4

8.0

0.12

2.4

44.8

2.16

4.01

0.1000

0.0601

400

23.2

8.0

0.12

2.4

47.6

2.52

4.87

0.0778

0.0470

500

26.4

8.0

0.12

2.5

51.3

2.98

6.01

0.0605

0.0366

630

30.1

8.0

0.12

2.6

55.2

3.54

7.43

0.0469

0.0283


6) 3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

2.5

0.1

2.0

34.6

1.13

1.58

1.2000

0.7270

35

6.9

2.5

0.1

2.1

36.8

1.29

1.92

0.8680

0.5240

50

8.2

2.5

0.1

2.2

39.8

1.51

2.36

0.6410

0.3870

70

9.7

2.5

0.1

2.3

43.2

1.81

3.04

0.4430

0.2680

95

11.3

2.5

0.1

2.4

46.9

2.17

3.87

0.3200

0.1930

120

12.8

2.5

0.1

2.4

50.1

2.53

4.69

0.2530

0.1530

150

14.2

2.5

0.1

2.5

53.3

2.90

5.60

0.2060

0.1240

185

15.9

2.5

0.1

2.6

57.2

3.40

6.77

0.1640

0.0991

240

18.3

2.6

0.1

2.8

63.2

4.12

8.55

0.1250

0.0754

300

20.4

2.8

0.1

3.0

69.0

4.89

10.46

0.1000

0.0601

400

23.2

3.0

0.1

3.4

76.7

6.10

13.18

0.0778

0.0470

500

26.4

3.2

0.1

3.6

85.7

8.10

16.55

0.0605

0.0366


7) 6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

3.4

0.1

2.1

38.7

1.30

1.75

1.2000

0.7270

35

6.9

3.4

0.1

2.2

40.9

1.47

2.22

0.8680

0.5240

50

8.2

3.4

0.1

2.3

43.9

1.70

2.50

0.6410

0.3870

70

9.7

3.4

0.1

2.4

47.3

2.02

3.25

0.4430

0.2680

95

11.3

3.4

0.1

2.5

51.0

2.42

4.12

0.3200

0.1930

120

12.8

3.4

0.1

2.6

54.4

2.79

4.95

0.2530

0.1530

150

14.2

3.4

0.1

2.7

57.6

3.17

5.87

0.2060

0.1240

185

15.9

3.4

0.1

2.8

61.5

3.69

7.06

0.1640

0.0991

240

18.3

3.4

0.1

2.9

66.9

4.38

8.82

0.1250

0.0754

300

20.4

3.4

0.1

3.1

71.8

5.11

10.68

0.1000

0.0601

400

23.2

3.4

0.1

3.3

78.3

6.24

13.32

0.0778

0.0470

500

26.4

3.4

0.1

3.5

86.4

7.63

16.50

0.0605

0.0366


8) 8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

6.0

4.5

0.1

2.3

43.9

1.57

2.02

0.9270

0.7270

35

6.9

4.5

0.1

2.4

46.0

1.75

2.38

0.6680

0.5240

50

8.2

4.5

0.1

2.4

48.8

2.00

2.85

0.4936

0.3870

70

9.7

4.5

0.1

2.5

52.3

2.34

3.57

0.3420

0.2680

95

11.3

4.5

0.1

2.6

55.9

2.75

4.45

0.2464

0.1930

120

12.8

4.5

0.1

2.7

59.4

3.16

5.32

0.1955

0.1530

150

14.2

4.5

0.1

2.8

62.6

3.57

6.27

0.1587

0.1240

185

15.9

4.5

0.1

2.9

66.4

4.07

7.45

0.1271

0.0991

240

18.3

4.5

0.1

3.1

72.0

4.82

9.25

0.0976

0.0754

300

20.4

4.5

0.1

3.3

77.0

5.71

11.28

0.0778

0.0601

400

23.2

4.5

0.1

3.4

83.2

6.78

13.86

0.0615

0.0470

500

26.4

4.5

0.1

3.5

91.1

8.20

17.32

0.0487

0.0366


9) 12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm2

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

-

 

 

 

 

 

 

 

 

35

6.9

5.5

0.1

2.4

50.3

2.00

2.63

0.8680

0.6680

50

8.2

5.5

0.1

2.5

53.3

2.26

3.11

0.6410

0.4936

70

9.7

5.5

0.1

2.6

56.8

2.62

3.85

0.4430

0.3420

95

11.3

5.5

0.1

2.8

60.6

3.07

4.77

0.3200

0.2464

120

12.8

5.5

0.1

2.9

64.1

3.49

5.65

0.2530

0.1955

150

14.2

5.5

0.1

3.0

67.3

3.91

6.61

0.2060

0.1587

185

15.9

5.5

0.1

3.1

71.2

4.44

7.81

0.1640

0.1271

240

18.3

5.5

0.1

3.3

76.8

5.21

9.64

0.1250

0.0976

300

20.4

5.5

0.1

3.3

81.3

6.10

11.66

0.1000

0.0778

400

23.2

5.5

0.1

3.5

87.7

7.20

14.28

0.0778

0.0615

500

26.4

5.5

0.1

3.8

96.0

9.15

17.80

0.0605

0.0487


10) 18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable

Normal Cross Section of Conductor

Normal Diameter of Conductor

Normal Thickness of Insulation

Normal Thickness of
Copper Tape

Normal Thickness of Outer Sheath

Approx.
Overall Dia.

Approx. Net Weight

Max. D.C. Resistance of Conductor at 20ºC

Al Conductor

Cu Conductor

Al Conductor

Cu Conductor

mm2

mm

mm

mm

mm

mm

kg/m

kg/m

Ω/km

Ω/km

25

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

50

8.2

8.0

0.1

2.9

64.9

3.02

3.87

0.6410

0.4936

70

9.7

8.0

0.1

3.0

68.4

3.42

4.65

0.4430

0.3420

95

11.3

8.0

0.1

3.1

72.0

3.89

5.59

0.3200

0.2464

120

12.8

8.0

0.1

3.3

75.7

4.39

6.54

0.2530

0.1955

150

14.2

8.0

0.1

3.3

78.7

4.85

7.55

0.2060

0.1587

185

15.9

8.0

0.1

3.4

82.6

5.42

8.79

0.1640

0.1271

240

18.3

8.0

0.1

3.5

88.0

6.22

10.66

0.1250

0.0976

300

20.4

8.0

0.1

3.7

92.9

7.20

12.77

0.1000

0.0778

400

23.2

8.0

0.1

3.9

99.3

8.38

15.46

0.0778

0.0615

500

26.4

8.0

0.1

4.2

107.6

10.15

18.85

0.0605

0.0487


 
Henan Jiapu Cable Group is located in Zhengzhou, the capital of Henan province, also politics, culture, economic and transport center. The group has 3 subsidiary companies which specialize in manufacturing and supplying various kinds of wires & cables. With more than 15 years of efforts and development, it has become an influential manufacturer of wires & cables making machinery in China.

The main products are as follows:

Bare Conductor (AAC, AAAC, ACSR, ACAR, AACSR, ACSR/AW)

Aerial Bundled Cable 1kV-35kV (ABC Cable)

PVC Insulated (Flexible ) Wire and PVC Insulated and Sheathed (Armoured) Power Cable

Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable

Welding Cable, Control Cable, Rubber Sheathed Cable

Fiber Optic Cable (OPGW, ADSS, etc. )

Fittings and Accessories (Suspension set, tension set, insulators, vibration dampers, joint box, terminal set, lightning arrester, etc. )

We can design and manufacture wires & cables according to the standards of GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Our products have been widely supplied to power utilities, electrical materials distributors and dealers, construction and engineering firms, electrical contractors or industrial companies all over the world, as well as Africa, Middle East, South-east Asia, South America, Central America, North America, Europe, Australia and so on. Welcome your OEM and ODM orders.

We are working hard all the time to improve the production lines, develop new products, focus on customer's needs, and try our best to offer the best professional services, strive to meet the customers' needs. We pursue the aim of "quality, reputation and service first" and adhere to the trade principals of "equality and mutual benefits". We win the trust of domestic customers and customers of different countries. We will take the enterprise spirit of "Unity and Striving, Reality and Innovating, Pioneering and Progressing, Honesty and Being Law-abiding". And we will cordially cooperate with friends of various circles both at home and abroad with a new gesture.

Send your message to this manufacturer

More >