Withair (Nanjing) Industries Co., Ltd. >> Ground Source Heat Pump with 45~65º C Hot Water Output

Ground Source Heat Pump with 45~65º C Hot Water Output

Ground Source Heat Pump with 45~65º C Hot Water Output
Price: US $ 25000-80000/Piece
Min Order: 1/Piece
Pay Type: L/C,T/T

-- About Withair® --

Withair® is a global provider of technical products and services for sustainability and resource management, specialize in heating & cooling system, air quality system and clean energy technology development and utilization,now it has three factories,manufacturing different kinds of products,and committed to providing the first-class products & system solutions for clients.

At Withair®, our aim is to support the growth, profit, and sustainability goals of our clients by delivering innovative solutions with n x value.we gain a deep understanding of our client's needs and business objectives first and foremost by gaining and leveraging our technical knowledge, innovative thinking, and vast equipment resources. from heating & cooling solutions and air quality management,to energy performance and efficiency determination,Withair® delivers the results.

Withair® products & solutions combine utmost efficiency with minimum energy consumption and strict respect of the environment, the idea proved to be a winning one in just a few years, Withair® became the leader in the sector !

Withair® has highly effective professional team to service customers

Known for their professionalism and personal integrity, Withair's highly skilled engineers, technicians, electricians, stable manufacturing workers, strict quality controller, and quick-reaction & professional after-service staff utilize their multi-disciplinary expertise in the creation and production of every solution.
 
Close cooperation among Withair's design, production and service teams - who are located under one roof and linked by advanced computerized systems - enables the Company to supply the widest possible range of products - from single units to very large quantities - while assuring rapid delivery and competitive pricing.


Ground/Water Source Heat Pumps - Each Withair® system installed, one more step towards a greener tommorrow

As we know, only two metres below the surface, the ground temperature remains a steady 10-12ºC throughout the year. By installing a ground source heat pump, you could utilise this natural geothermal energy to provide a reliable and renewable cooling, heating and hot water system for your building.When the sun shines, the heat pump's borehole/ ground source heating coil gets a chance to recover and replenish. This also increases the heat pump's service life because it can rest during much of the year. 

By installing Withair® a Geothermal Heat Pump, you could utilise this natural heat energy to provide a reliable and renewable heating and hot water system for your home, you can reduce costs by up to 80 % compared to direct electricity, depending on where you live, the living area, the choice of heat pump and whether you use a cooling function or not. All this while keeping noise levels exceptionally low.

Withair® the W01R series heat pumps involve a range of 282 models, with heating and cooling capacity among 2.6kW and 3,200kW, which allow to create "customized" solution, matching the different installations requests.



-- Product Description --

Withair® Ground Source Heat Pump with 45~65ºC Hot Water Output is widely used in plastic industry, electroplating industry, food processing,chemical industry and other process cooling applications of modern manufacturing industries which needs a lot of high temperature hot water.It is the mature products which are equipped with newly-developed semi-hermetic screw compressors and use dry type or flooded type evaporator, which result in lower noise and lower vibration, reliable long period operation, and installation feasibility on any floor of the building.The units are composed of a compressor(s), a condenser(s),a direct-expansion water cooler, a electronic expansion valve(s),and auxiliary and control equipment.Optimized system design and enhanced heat exchange efficiency makes the unit working best under both full load and partial load. Stepless capacities can be customized.The units can be operated with the utmost simplicity.



-- The Key Advantages Include --

Uses environmentally-friendly R134a refrigerant.

Capable of heating water range:45 ~ 65°C

Using for advanced semi-enclosed screw type compressor
The international advanced double-screw semi-enclosed compressor, through slide valve achieve mmultiple-stage or sectionless of adjustment,to adapt to changes in load of smooth and compressor built-in efficient oil separator, the rate can reach 99.7%,using differential injection,no pump, oil, safe and reliable guarantee mechanism for the safe and stable operation, long service life.

Energy-saving
*  Unit adopts PLC control technology, according to user load demand changes through intelligent control, multilevel energy regulation in full or part of the unit that can reach the best energy efficiency, reduce the operating cost.
* Provide multilevel (0-25% to 50% &75% - 100%) and the energy level adjustment methods for your choice.

Intellectualized control, simple operation
* Unit adopts PLC control technology, "a key start" and automatic operation.
* In the man-machine interface screen English display, touch screen/LCD text interface for your option.
* Units with remote control functions: turbine control system with built-in WEB browser,users can pass on any computer through internet in the remote monitoring and control unit can operation conditions and parameters of the work unit, the query of the unit.

Protection function origin
* Units provided the refrigeration system, electrical system and the water system of the complete protection function, ensure its safe operation.
* Unit Settings: unit of power of inverse phase), (high/low refrigeration system protection, oil is too low to high temperature, vent protection system to protect and water flow protection, antifreeze protection safety protection function, guarantee the safe and stable operation of the mechanism.

Heat recovery function
* Units can be based on user needs, increase the heat recovery function, at the same time in refrigeration heat side will recycle waste heat utilization,and use side and heat side, improved the two-way unit running condition, improve the efficiency of the unit, the unit greatly reduce the operation cost.
* Partial heat recovery and total heat recovery.

Advanced design, superior performance of high-efficiency heat exchanger
* Shell and tube evaporator within the evaporator using the latest threaded efficient heat exchange tube and tube with high heat efficiency,combined with poor casing baffle slabs of chilled water flow and circuitous increased turbulence effect, make the evaporator heat transfer coefficient has been greatly improved,and the latest flame retardant, use shell heat preservation material, energy loss and ensure the good performance of refrigeration unit.



-- Technical Data --

Ground Source Heat Pump with 45ºC Hot Water Output
Single compressor system
Model  W01R2 110S1M150S1M200S1M240S1M300S1M330S1M360S1M410S1M480S1M530S1M560S1M640S1M
Cooling conditionnominal cooling capacitykW127.6174.4232.4278.4348.2382.8417.6475.6556.8614.8649.6742.4
nominal cooling capacityTR36.349.666.179.299.0108.8118.7135.2158.3174.8184.7211.1
input power(kW)kW22.530.139.646.858.964.869.977.689.499.1103.4115.4
chilled water flowm3/h2230.140.148.260.265.971.981.995.9106.4112128
chilled water pressure dropkPa505355586061626363646565
cooling water flowm3/h11.816.321.425.632.635.138.243.450.75659.167.2
cooling water pressure dropkPa353738394040424244444545
Heating conditionnominal heating capacitykW136.2184.4241.5287.2361.4392.7426.1484.3572.9631.5663.4752.6
nominal heating capacityTR38.752.468.781.7102.8111.7121.2137.7162.9179.6188.6214.0
input powerkW29.339.251.66176.784.491.1101116.4139.1134.6150.1
chilled water flowm3/h11.816.321.425.632.635.138.243.450.75659.167.2
chilled water pressure dropkPa222425262728303234363840
hot water flowm3/h2230.140.148.260.265.971.981.995.9106.4112128
hot water pressure dropkPa384142434344444546474749
Power supplyV/Ph/Hz380/3/50
Starting mode Y-
Energy control % 0-25-50-75-100
Condensortype Shell and tube heat exchanger 
pipe diameter DN65DN65DN80DN80DN100DN100DN125DN125DN125DN125DN125DN150
Evaporatortype Dry expansion evaporator 
pipe diameter DN65DN65DN80DN80DN100DN100DN125DN125DN125DN125DN125DN150
Compressor Screw type
Refrigerant R134A
Throttle mode Thermal expansion valve
Dimensionlengthmm295030003000303030503050310031003150335033503400
widthmm5506507508409001000105011001150120012501320
heightmm155016501750175018501950209021502220233023702440
Unit weightkg120015001850216025502740290031503350350035503700
Working weightkg130016202080235027702990315034203640380039004080

Twin compressors system

Model  W01R2 220S2M300S2M400S2M480S2M600S2M660S2M720S2M820S2M960S2M1060S2M1120S2M1280S2M
Cooling conditionnominal cooling capacitykW255.2348.8464.8556.8696.4765.6835.2951.21113.61229.61299.21484.8
nominal cooling capacityTR72.699.2132.2158.3198.0217.7237.5270.5316.6349.6369.4422.2
input power(kW)kW4560.279.293.6117.8129.6139.8155.2178.8198.2206.8230.8
chilled water flowm3/h4460.280.296.4120.4131.8143.8163.8191.8212.8224256
chilled water pressure dropkPa555860626464666667676870
cooling water flowm3/h23.632.642.851.265.270.276.486.8101.4112118.2134.4
cooling water pressure dropkPa384042434444454648484949
Heating conditionnominal heating capacitykW272.4368.8483574.4722.8785.4852.2968.61145.812631326.81505.2
nominal heating capacityTR77.5104.9137.3163.3205.5223.3242.3275.4325.8359.1377.3428.0
input powerkW58.678.4103.2122153.4168.8182.2202232.8258.2269.2300.2
chilled water flowm3/h23.632.642.851.265.270.276.486.8101.4112118.2134.4
chilled water pressure dropkPa252628303334363840424446
hot water flowm3/h4460.280.296.4120.4131.8143.8163.8191.8212.8224256
hot water pressure dropkPa404142444545464647485051
Power supplyV/Ph/Hz380/3/50
Starting mode Y-
Energy control % 0-25-50-75-100
Condensortype Shell and tube heat exchanger 
pipe diameter 2*DN652*DN652*DN802*DN802*DN1002*DN1002*DN1252*DN1252*DN1252*DN1252*DN1252*DN150
Evaporatortype Dry expansion evaporator 
pipe diameter DN80DN100DN125DN125DN150DN150DN150DN150DN200DN200DN200DN200
Compressor Screw type
Refrigerant R134A
Throttle mode Thermal expansion valve
Dimensionlengthmm330033203450358036003700380039604060415042004200
widthmm118012001260132013801420150015001540157016001600
heightmm160016901800194020502070215022002380246025002500
Unit weightkg265028503500390046004900510056006080650070007700
Working weightkg278030603850430050505400565062006800730079008700

Fourfold compressors system

Model  W01R2 960S4M1200S4M1320S4M1440S4M1640S4M1920S4M2120S4M2240S4M2560S4M
Cooling conditionnominal cooling capacitykW1113.61392.81531.21670.41902.42227.22459.22598.42969.6
nominal cooling capacityTR316.6396.0435.4475.0540.9633.3699.2738.8844.4
input power(kW)kW187.2235.6259.2279.6310.4357.6396.4413.6461.6
chilled water flowm3/h192.8240.8263.6287.6327.6383.6425.6448512
chilled water pressure dropkPa656969707273737580
cooling water flowm3/h102.4130.4140.4152.8173.6202.8224236268.8
cooling water pressure dropkPa454648494950505252
Heating conditionnominal heating capacitykW1148.81445.61570.81704.41937.22291.625262653.63010.4
nominal heating capacityTR326.6411.0446.6484.6550.8651.6718.2754.5856.0
input powerkW244306.6337.6364.4404465.6516.4538.4600.4
chilled water flowm3/h102.4130.4140.4152.8173.6202.8224236.4268.8
chilled water pressure dropkPa404244464850525558
hot water flowm3/h192.8240.8263.6287.6327.6383.6425.6448512
hot water pressure dropkPa505151525354545556
Power supplyV/Ph/Hz380/3/50
Starting mode Y-
Energy control % 0-25-50-75-100
Condensortype Shell and tube heat exchanger 
pipe diameter 2*DN1252*DN1502*DN1502*DN1502*DN1502*DN2002*DN2002*DN2002*DN200
Evaporatortype Dry expansion evaporator 
pipe diameter 2*DN1252*DN1502*DN1502*DN1502*DN1502*DN2002*DN2002*DN2002*DN200
Compressor Screw type
Refrigerant R134A
Throttle mode Thermal expansion valve
Dimensionlengthmm480049005000500050505050510051005100
widthmm187019001930197020002060210021002200
heightmm207020902190223023002400250025202600
Unit weightkg87009100943096001000010500110001170012800
Working weightkg9300965010020102001070011300118001250013700


Ground Source Heat Pump with 65ºC Hot Water Output
Single compressor system

 

Model  W01R2 110S1H150S1H200S1H240S1H300S1H330S1H360S1H410S1H480S1H530S1H560S1H640S1H
Cooling conditionnominal cooling capacitykW127.6174.4232.4278.4348.2382.8417.6475.6556.8614.8649.6742.4
nominal cooling capacityTR36.349.666.179.299.0108.8118.7135.2158.3174.8184.7211.1
input power(kW)kW22.530.139.646.858.964.869.977.689.499.1103.4115.4
chilled water flowm3/h2230.140.148.260.265.971.981.995.9106.4112128
chilled water pressure dropkPa505355586061626363646565
cooling water flowm3/h11.816.321.425.632.635.138.243.450.75659.167.2
cooling water pressure dropkPa353738394040424244444545
Heating conditionnominal heating capacitykW124.8169.2223267335.2370.3401.8453.8530.2585.4618.6704.6
nominal heating capacityTR35.548.163.475.995.3105.3114.2129.0150.8166.4175.9200.3
input powerkW41.856.173.787.1109.6120.6130.1144.3166.3184.5192.4214.4
chilled water flowm3/h11.816.321.425.632.635.138.243.450.75659.167.2
chilled water pressure dropkPa222425262728303234363840
hot water flowm3/h2230.140.148.260.265.971.981.995.9106.4112128
hot water pressure dropkPa384142434344444546474749
Power supplyV/Ph/Hz380/3/50
Starting mode Y-
Energy control % 0-25-50-75-100
Condensortype Shell and tube heat exchanger 
pipe diameter DN65DN65DN80DN80DN100DN100DN125DN125DN125DN125DN125DN150
Evaporatortype Dry expansion evaporator 
pipe diameter DN65DN65DN80DN80DN100DN100DN125DN125DN125DN125DN125DN150
Compressor Screw type
Refrigerant R134A
Throttle mode Thermal expansion valve
Dimensionlengthmm295030003000303030503050310031003150335033503400
widthmm5506507508409001000105011001150120012501320
heightmm155016501750175018501950209021502220233023702440
Unit weightkg120015001850216025502740290031503350350035503700
Working weightkg130016202080235027702990315034203640380039004080

Twin compressors system

Model  W01R2 220S2H300S2H400S2H480S2H600S2H660S2H720S2H820S2H960S2H1060S2H1120S2H1280S2H
Cooling conditionnominal cooling capacitykW255.2348.8464.8556.8696.4765.6835.2951.21113.61229.61299.21484.8
nominal cooling capacityTR72.699.2132.2158.3198.0217.7237.5270.5316.6349.6369.4422.2
input power(kW)kW4560.279.293.6117.8129.6139.8155.2178.8198.2206.8230.8
chilled water flowm3/h4460.280.296.4120.4131.8143.8163.8191.8212.8224256
chilled water pressure dropkPa555860626464666667676870
cooling water flowm3/h23.632.642.851.265.270.276.486.8101.4112118.2134.4
cooling water pressure dropkPa384042434444454648484949
Heating conditionnominal heating capacitykW249.6338.4446535.8670.4740.6803.6907.61060.41170.81237.21409.2
nominal heating capacityTR71.096.2126.8152.3190.6210.6228.5258.1301.5332.9351.8400.7
input powerkW83.6112.2147.4174.2219.2241.2260.2288.6332.6369384428.8
chilled water flowm3/h23.632.642.851.265.270.276.486.8101.4112118.2134.4
chilled water pressure dropkPa252628303334363840424446
hot water flowm3/h4460.280.296.4120.4131.8143.8163.8191.8212.8224256
hot water pressure dropkPa404142444545464647485051
Power supplyV/Ph/Hz380/3/50
Starting mode Y-
Energy control % 0-25-50-75-100
Condensortype Shell and tube heat exchanger 
pipe diameter 2*DN652*DN652*DN802*DN802*DN1002*DN1002*DN1252*DN1252*DN1252*DN1252*DN1252*DN150
Evaporatortype Dry expansion evaporator 
pipe diameter DN80DN100DN125DN125DN150DN150DN150DN150DN200DN200DN200DN200
Compressor Screw type
Refrigerant R134A
Throttle mode Thermal expansion valve
Dimensionlengthmm330033203450358036003700380039604060415042004200
widthmm118012001260132013801420150015001540157016001600
heightmm160016901800194020502070215022002380246025002500
Unit weightkg265028503500390046004900510056006080650070007700
Working weightkg278030603850430050505400565062006800730079008700

Fourfold compressors system

Model  W01R2 960S4H1200S4H1320S4H1440S4H1640S4H1920S4H2120S4H2240S4H2560S4H
Cooling conditionnominal cooling capacitykW1113.61392.81531.21670.41902.42227.22459.22598.42969.6
nominal cooling capacityTR316.6396.0435.4475.0540.9633.3699.2738.8844.4
input power(kW)kW187.2235.6259.2279.6310.4357.6396.4413.6461.6
chilled water flowm3/h192.8240.8263.6287.6327.6383.6425.6448512
chilled water pressure dropkPa656969707273737580
cooling water flowm3/h102.4130.4140.4152.8173.6202.8224236268.8
cooling water pressure dropkPa454648494950505252
Heating conditionnominal heating capacitykW1071.61340.81481.21607.21815.22120.82341.62474.42818.4
nominal heating capacityTR304.7381.2421.2457.0516.1603.0665.8703.6801.4
input powerkW348.4438.4482.4520.4577.2665.2738769.6857.6
chilled water flowm3/h102.4130.4140.4152.8173.6202.8224236.4268.8
chilled water pressure dropkPa404244464850525558
hot water flowm3/h192.8240.8263.6287.6327.6383.6425.6448512
hot water pressure dropkPa505151525354545556
Power supplyV/Ph/Hz380/3/50
Starting mode Y-
Energy control % 0-25-50-75-100
Condensortype Shell and tube heat exchanger 
pipe diameter 2*DN1252*DN1502*DN1502*DN1502*DN1502*DN2002*DN2002*DN2002*DN200
Evaporatortype Dry expansion evaporator 
pipe diameter 2*DN1252*DN1502*DN1502*DN1502*DN1502*DN2002*DN2002*DN2002*DN200
Compressor Screw type
Refrigerant R134A
Throttle mode Thermal expansion valve
Dimensionlengthmm480049005000500050505050510051005100
widthmm187019001930197020002060210021002200
heightmm207020902190223023002400250025202600
Unit weightkg87009100943096001000010500110001170012800
Working weightkg9300965010020102001070011300118001250013700

Notes:

1.These parameter were tested according to pure water,not include anti-freezing liquid and water pump power;
2.Units can realize 1~24 unit's modular connection and control energy-regulation automatically.
3.All models, sizes, dimensions, and specifications are subject to change without prior notice, please refer to nameplates for the most accurate specifications.


Ground Loop Working Condition:
1. Cooling standard working condition: User side inlet/outlet water temperature 12ºC/7ºC; Source side inlet/outlet water temperature 25ºC/30ºC;
2. Heating standard working condition: User side inlet/outlet water temperature 40ºC/45ºC; Source side inlet water temperature 10ºC;

Ground Water Working Condition:
1. Cooling standard working condition: User side inlet/outlet water temperature 12ºC/7ºC; Source side inlet/outlet water temperature 18ºC/29ºC;
2. Heating standard working condition: User side inlet/outlet water temperature 40ºC/45ºC; Source side inlet water temperature 15ºC;

Water Lopp Working Condition:
1. Cooling standard working condition: User side inlet/outlet water temperature 12ºC/7ºC; Source side inlet/outlet water temperature 30ºC/35ºC;
2. Heating standard working condition: User side inlet/outlet water temperature 40ºC/45ºC; Source side inlet water temperature 20ºC;



-- Quality Supply Chain System --




-- Withair® Production Lines --




-- Withair® Certificates and Awards --




-- Payment terms --

Payment termsT/TEXW50% in advance, 50% before delivery
FOB
CFR
CIF
L/CTotal amount above USD100,000, we accept L/C at sight



-- Delivery & Packaging --

*  100% test before deliverying products.
*  Products catalogue, installation & operation manual will be sent together.
*  Tracking number will be sent to customer as soon as we ship the products.
*  Item shipped in 25 working days against payment depends on the quantity.
*  Four steps of pakacges, plastic film, foam, carton and plywood for stable transporation.
*  Ocean shipping, railway shipment and air transportation are acceptable according to customer demand.



-- Installation Instruction --





-- Case Studies & Quality Service --

Withair is a experienced partner in designing, installing small to large scale projects in the HVACR field of engineering systems for built environment of the further !
 
Withair Provides Global Installation Services:
We have developed close, long-term relationships with consultants, contractors, builders, and installers 
around the world. Teams of technical personnel are often sent to assist these partners in the design and implentation of large projects, and in the preparation of tenders for a variety of joint ventures. Among our worldwide installations are major shopping centers, industrial parks, schools, office buildings, hospitals, restaurants, convention centers, showrooms, green houses, commercial and residential buildings, swimming pools, mobile communication centers, and special projects. 





-- FAQ --

Q1. Can I have a sample order for Withair' products ?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
 
Q2. What about the delivery time ?
A: Sample needs 15 days, mass production time needs 2-3 weeks for order quantity more than one container
 
Q3. Do you have any MOQ limit for Withair' products ?
A: Low MOQ, 1pc for sample checking is available


Q4. What is Withair® certification ?
A:  The certificate we have include: CE, RoHs,SGS, CE, UL, ISO9001. ISO18001, ISO14001, national Lab inspecton report, technology patents and so on.

Q5. Where are Withair' products installed till now ?
A: Currently Withair' products has been installed China, Europe, Africa, Middle-East, U.S.A, South American and so on.

Q6. Withair® Agent's & Distributor's Benefits ?
A: *  Favorable prices & high quality products.

    *  New business opportunities & profits.
    *  Free of charge for brochures & technical data.
    *  Training for products of technical & marketing.
    *  Customer resources sharing in the territory.
    *  On-site support from sales & service team.

Q7. How to proceed an order for Withair' products ?
A: Firstly let us know your requirements or application.
Secondly We provide solution according to local weather conditions.
Thirdly customer confirms the samples and formal order.
Fourthly We arrange the production.
 
Q8. Is it OK to print my logo on Withair' products ?
A: Yes. legal OEM brand is accepted. Please inform us formally before our production and confirm the logo design firstly.
 
Q9: Do you offer guarantee for the products ?
A: Yes, we offer 3-5 years warranty to our products.
 
Q10: How to deal with the faulty ?
A: Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.3%.
Secondly, during the guarantee period, we will send spare parts with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.



-- CONTACT US --

Thank you for visiting our website, further questions please feel free to contact us. We will do our best to support you all the time.





 

Prod Model: W01R2 Series
Energy Efficiency Grade: One
Heat Temperature: 50-70°c
Heating Type: Circulating Heat
Withair® Is a global provider of technical products and services for sustainability and resource management, specialize in heating & cooling system, air quality system and clean energy technology development and utilization, and Digital Printing Machine, Eco Solvent Printer, UV Flatbed Printer and Hybrid & Industrial UV printer, , now it has three factories, manufacturing different kinds of products, and committed to providing the first-class products & system solutions for clients.

At Withair® , our aim is to support the growth, profit, and sustainability goals of our clients by delivering innovative solutions with n X value. We gain a deep understanding of our client's needs and business objectives first and foremost by gaining and leveraging our technical knowledge, innovative thinking, and vast equipment resources. From heating & cooling solutions and air quality management, to energy performance and efficiency determination, Withair® Delivers the results.

Withair® Products & solutions combine utmost efficiency with minimum energy consumption and strict respect of the environment, the idea proved to be a winning one in just a few years, Withair® Became the leader in the sector!

Withair® Has highly effective professional team to service customers

Known for their professionalism and personal integrity, Withair's highly skilled engineers, technicians, electricians, stable manufacturing workers, strict quality controller, and quick-reaction & professional after-service staff utilize their multi-disciplinary expertise in the creation and production of every solution.

Close cooperation among Withair's design, production and service teams - who are located under one roof and linked by advanced computerized systems - enables the Company to supply the widest possible range of products - from single units to very large quantities - while assuring rapid delivery and competitive pricing.

Send your message to this manufacturer

  • Withair (Nanjing) Industries Co., Ltd.

More >

Other Products with This Manufacturers